Troubleshooting
6-17
P/N 7105144G
2008 Nordson Corporation
VersaBlue_NW
Problem
Possible Cause
Corrective Action
Motor overheated
Ambient temperature too high
Decrease ambient temperature by
cooling or airing out
Fan cap dirty
Clean
Pump blocked by foreign matter
Replace pump
Pump operates too sluggish
Replace pump
Material too cold
Set temperature accordingly
Motor defective
−
Replace
Motor not supplied with
voltage
−
Technical inspection
Motor controller fault
⇒
Switch melter off and on again with
main switch
Motor overheated
Refer to
Motor overheated
Motor controller overheated
Decrease ambient temperature by
cooling or airing out
Clean cooling section of motor
controller
Short circuit
Check motor power
Overload (pump blocked by
foreign matter, pump too sluggish,
material too cold)
Refer to
Motor overheated
Motor controller
defective
−
Replace
NOTE:
If more than one motor
controller has been replaced, the
screen
Motor controller replacement
appears. Refer to section
Repair,
Replacing Motor Controller
.
No Line Speed Signal (Voltage / Current / Frequency)
Problem
Possible Cause
Corrective Action
Parent machine not
operating
−
Start up parent machine
Polarity of line speed
voltage input is reversed
−
Reverse polarity
Encoder defective
−
Replace
Содержание VersaBlue VB Series
Страница 40: ...Introduction 2 14 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Страница 66: ...Installation 3 26 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Страница 150: ...Operation 4 84 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Страница 174: ...Maintenance 5 24 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Страница 236: ...Parts 8 2 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Страница 250: ...Options 10 6 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Страница 254: ...Password A 4 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Страница 280: ...Glossary D 16 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...