Installation
3-15
P/N 7105144G
2008 Nordson Corporation
VersaBlue_NW
NOTE:
Contact rating max. 24 V
DC
/2 A
Digital outputs
Pin
Contact
Function
17
Make
contact
24 V: External solenoid valve 1 is triggered
0 V: External solenoid valve 1 is not triggered
18
19
Make
contact
24 V: External solenoid valve 2 is triggered
0 V: External solenoid valve 2 is not triggered
20
21
Make
contact
24 V: External solenoid valve 3 is triggered
0 V: External solenoid valve 3 is not triggered
22
23
Make
contact
24 V: External solenoid valve 4 is triggered
0 V: External solenoid valve 4 is not triggered
24
25
24 V
DC
External (customer’s; to be connected by customer)
26
Make
contact
24 V: System ready
0 V: System not ready
27
Break
contact
24 V: No general alarm
−
warning
−
0 V: General alarm
−
warning
−
28
Break
contact
24 V: No general alarm
−
fault
−
0 V: General alarm
−
fault
−
Pin 29 not assigned
30
Make
contact
Contact closed: Pressure build-up completed
Contact open: Pressure build-up not completed
31
Make
contact
With option
Level display
Contact closed: Fill tank
Contact open: Do not fill tank
32
NOTE:
Pins 31 and 32 are not assigned with the options
Level control
and
Level
control with overflow protection
. Instead, there is the interface
Level control
that
triggers the filling valve.
Содержание VersaBlue VB Series
Страница 40: ...Introduction 2 14 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Страница 66: ...Installation 3 26 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Страница 150: ...Operation 4 84 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Страница 174: ...Maintenance 5 24 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Страница 236: ...Parts 8 2 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Страница 250: ...Options 10 6 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Страница 254: ...Password A 4 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Страница 280: ...Glossary D 16 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...