NORDAC FLEX (SK 200E ... SK 235E) – Users Manual for Frequency Inverters
38
BU 0200 en-US-4920
2 Mounting and installation
Pos : 71 /Anl eitungen/ Elek tronik/FU und Start er/ 2. M ont age und Ins tall ati on/M ont age/M ot ormont age - St andard [SK 1xx E, SK 2xxE]/M ontage "G erät" [ SK 1x xE / SK 2xx E] @ 1\m od_1341484255223_14638.docx @ 29902 @ 2 @ 1
2.1 Mounting SK 2xxE
The devices are available in various sizes depending on their output. They can be mounted on the
terminal box of a motor or in its immediate vicinity.
Motor-mounted version
Wall-mounted version
When a complete drive unit (gear unit + motor + SK 2xxE) is delivered, the device is always fully
installed and tested.
Information
Device version IP6x
IP6x-compliant devices must be installed by NORD since special measures have to be taken. IP6x components
that are retrofitted on site cannot guarantee this degree of protection.
Pos : 72 /Anl eitungen/ Elek tronik/FU und Start er/ 2. M ont age und Ins tall ati on/M ont age/M ot ormont age - St andard [SK 1xx E, SK 2xxE]/M ontage "G erät"_Ergänzung 1 [ SK 2xx E] @ 7\m od_1434102314079_14638.docx @ 224573 @ @ 1
The SK 2xxE is connected to the motor or the wall mounting kit using the size that is suitable for the
SK TI4-… connection unit . The connection unit can also be ordered separately for subsequent
mounting on an existing motor or to replace a different motor-mounted variable frequency drive.
The
Connection Unit SK TI4
module includes the following components:
• Cast housing, seal (already glued in) and insulation plate
• Power terminal block in accordance with line power connection
• Control terminal block in accordance with SK 2xxE version
• Screw kit for mounting on the motor and terminal blocks
• Ready-made cables for motor and PTC thermistor connection
•
Size 4 only:
From hardware status "EAA" (variable frequency drive) or "EA" (connection unit)
toroidal core (ferrite) with fastening material
Pos : 73 /Anl eitungen/ Elek tronik/FU und Start er/ 2. M ont age und Ins tall ati on/M ont age/M ot ormont age - St andard [SK 1xx E, SK 2xxE]/M ontage "G erät"_Ergänzung 2 [ SK 1x 0E / SK 2xxE] @ 7\mod_1434103340270_14638. doc x @ 224637 @ @ 1