5 Parameter
BU 0200 en-US-4920
201
Pos : 537 /Anleit ungen/El ektr onik /FU und St art er/5. Par ameter/ Par ameter auflist ung (P000 .. .)/P500- P599/Param et er P541 – Rel ais und digital e Ausg äng e s etz en [ SK 2x xE, SK 2xx E-FDS] @ 2\m od_1346932170278_14638.docx @ 43268 @ @ 1
P541
Set relays
(set digital output)
S
0000 ... FFF (hex)
{ 0000 }
This function provides the opportunity to control the relay and the digital outputs independently of
the variable frequency drive status. To do this, the relevant output must be set to the function
"External control".
This function can either be used manually or in combination with a bus control.
Bit 0 =
Digital output 1
Bit 6 =
Bus/An/Dig Out Bit 5,
"Bus/Analog/Digital Out Bit 5"
Bit 1 =
Bus/AS-i Out Bit 0
Bit 7 =
Bus digital output 7
Bit 2 =
Bus/AS-i Out Bit 1
Bit 8 =
Bus digital output 8
Bit 3 =
Bus/AS-i Out Bit 2
Bit 9 =
Bus statusword Bit10
Bit 4 =
Bus/AS-i Out Bit 3
Bit 10 =
Bus statusword Bit13
Bit 5 =
Bus/An/Dig Out Bit 4,
"Bus/Analog/Digital Out Bit 4"
Bit 11 =
Digital output 2
Bits 8-11
Bits 7-4
Bits 3-0
Min. value
0000
0
0000
0
0000
0
Binary
hex
Max. value
1111
F
1111
F
1111
F
Binary
hex
Changes which are made to the settings are not saved in the EEPROM. After "Power ON" of the
variable frequency drive, the parameter is therefore in the default setting.
Setting of the value via …
BUS:
The corresponding hex value is written into the parameter, thereby setting the
relay and digital outputs.
Simple Box:
The hexadecimal code is entered directly when the Simple Box is used.
Parameter Box:
Each individual output can be separately called up in plain text and activated.
Pos : 538 /Anleit ungen/El ektr onik /FU und St art er/5. Par ameter/ Par ameter auflist ung (P000 .. .)/P500- P599/Param et er P542 – Analogausgang s etz en [ SK 1x 0E, SK 2x xE, SK 2xx E-FDS] @ 2\mod_1346932170902_14638.docx @ 43292 @ @ 1
P542
[-01]
[-02]
Set analog output
(set analog output)
S
0.0 ... 10.0 V
{ all 0.0 }
... only with
SK CU4-IOE or
SK TU4-IOE
[-01] =
IOE-1, AOUT of the
first
I/O extension (SK xU4IOE)
[-02] =
IOE-2, AOUT of the
second
I/O extension (SK xU4IOE)
The analog output of the VFD can be set with this function, independently of the actual operating
state. To do this, the relevant analog output must be set to the function "External control" (P418 =
7).
This function can either be used manually or in combination with a bus control. The value set here
will, once confirmed, be produced at the analog output.
Changes which are made to the settings are not saved in the EEPROM. After "Power ON" of the
variable frequency drive, the parameter is therefore in the default setting.
Pos : 539 /Allgem ein/ Allgem eingültig e Module/---------Seitenumbr uc h k ompakt --------- @ 13\m od_1476369695906_0. doc x @ 2265496 @ @ 1
Содержание NORDAC FLEX SK 2 E-111-123-A Series
Страница 1: ...BU 0200 en US NORDAC FLEX SK 200E SK 235E Users Manual for Frequency Inverters...
Страница 5: ...Publisher BU 0200 en US 4920 5...
Страница 283: ...Key word index BU 0200 en US 4920 283...
Страница 284: ...6072003 4920...