6 Operating status messages
BU 0200 en-US-4920
233
Pos : 696 /Anleit ungen/El ektr onik /FU und St art er/6. M eldung en zum Betriebsz ust and/Mel dungen Eins chalts perre (T abellenüberschrif t) @ 3\m od_1361803467385_14638.docx @ 59942 @ 5 @ 1
Notifications switch-on block, "not ready"
Display in the
SimpleBox /
ControlBox
Reason:
Text in the ParameterBox
Cause
•
Remedy
Group
Details in
P700 [-03]
Pos : 697 /Anleit ungen/El ektr onik /FU und St art er/6. M eldung en zum Betriebsz ust and/Störm eldung en (Auflist ung)/I nf ormation I 000_01 [SK 180E . .. SK 5x xE/SK 500P] @ 2\mod_1347457775195_14638. doc x @ 47348 @ @ 1
I000
0.1
Disable voltage from IO
If the "disable voltage" function is parameterized, input
(P420/P480) is Low
•
"Set high" input
•
Check signal cable (broken cable)
0.2
IO fast stop
If the function "fast stop" is parameterized, input
(P420/P480) is at low
•
"Set high" input
•
Check signal cable (broken cable)
0.3
Block voltage from bus
•
Bus operation (P509): control word bit 1 is "low"
0.4
Bus fast stop
•
Bus operation (P509): control word bit 2 is "low"
0.5
Enable on start
Enable signal (control word, Dig I/O or Bus I/O) was already
applied during the initialization phase (after line power "ON",
or control voltage "ON"). Or electrical phase is lacking.
•
Only issue enable signal after completion of
initialization (i.e. when the VFD is ready)
•
Activation of "Automatic Start" (P428)
0.6 – 0.7
Reserved
Information message for PLC
see supplementary
instructions
Pos : 698 /Anleit ungen/El ektr onik /FU und St art er/6. M eldung en zum Betriebsz ust and/Störm eldung en (Auflist ung)/I nf ormation I 000_02-Erg änz ung 08 und 09 [ SK 180E ... SK 5xx E/ SK 500P] @ 10\mod_1455725649528_14638. docx @ 306333 @ @ 1
0.8
Right direction blocked
Switch-on block with inverter shut-off activated by:
P540
or by "Enable right block"
(P420
= 31, 73) or "Enable
left block" (
P420
= 32, 74),
The variable frequency drive switches to "Ready for
switching on" status
0.9
Left direction blocked
Pos : 699 /Anleit ungen/El ektr onik /FU und St art er/6. M eldung en zum Betriebsz ust and/Störm eldung en (Auflist ung)/I nf ormation I 006 [SK 180E . .. SK 5xxE, auß er SK 500P] @ 2\m od_1347457929759_14638. docx @ 47373 @ @ 1
I006
1)
6.0
Charging error
Charging relay not energized, because:
•
Line/DC link voltage too low
•
Line voltage failure
•
Evacuation run active ((P420)/(P480))
Pos : 700 /Anleit ungen/El ektr onik /FU und St art er/6. M eldung en zum Betriebsz ust and/Störm eldung en (Auflist ung)/I nf ormation I 011 [SK 180E . .. SK 5xxE/SK 500P] @ 2\mod_1347457936856_14638. docx @ 47398 @ @ 1
I011
11.0
Analog Stop
If an analog input of the variable frequency drive or a
connected IO extension is configured to detect cable breaks
(2-10 V signal or 4-20 mA signal), the variable frequency
drive switches to the status "ready for switch-on" if the
analog signal undershoots the value
1 V
or
2 mA
This also occurs if the relevant analog input is
parameterized to function "0" ("no function").
•
Check connection
Pos : 701 /Anleit ungen/El ektr onik /FU und St art er/6. M eldung en zum Betriebsz ust and/Störm eldung en (Auflist ung)/I nf ormation I 014 "res erviert" [SK 200E . .. SK 5xxE/ SK 500P] @ 2\m od_1347457944329_14638. docx @ 47423 @ @ 1
I014
1)
14.4
Reserved
Information message for POSICON
see supplementary
manual
Pos : 702 /Anleit ungen/El ektr onik /FU und St art er/6. M eldung en zum Betriebsz ust and/Störm eldung en (Auflist ung)/I nf ormation I 018 "res erviert" [SK 2xx E/ SK 5xxE/ SK 2xx E-FDS/SK 500P] @ 2\m od_1347457946544_14638. docx @ 47448 @ @ 1
I018
1)
18.0
Reserved
Information message for "Safe stop" function
see
supplementary manual
Pos : 703 /Anleit ungen/El ektr onik /FU und St art er/6. M eldung en zum Betriebsz ust and/Störm eldung en (Auflist ung)/I nf ormation - Kennzeic hnung "Nic ht ber eit" @ 20\mod_1513067472948_14638.docx @ 2375119 @ @ 1
1)
Indication of operating mode (message) on the
Parameter Box
or virtual operating unit of the
NORD CON-Software
:
"Not ready"
Pos : 705 /Anleit ungen/El ektr onik /FU und St art er/6. M eldung en zum Betriebsz ust and/FAQ Betriebsst örungen @ 9\mod_1448963314277_14638. doc x @ 268441 @ 2 @ 1