ELECTRICAL
WARNING
!
It is critical that the AGS system be turned o
ff
any time the generator is going to be serviced.
Failure to deactivate the AGS system may result in
damage, injury, or death if the Genset should start
unexpectedly. Also, if the AGS system is set and
the generator is turned o
ff
at any switch, it will
clear the AGS settings.
Operation
The generator can be started from the
rocker switch on the dash, from other
remote start switches (if equipped), from the
start switch on the generator itself, or from
the SilverLeaf touchscreen (if equipped).
The generator in your coach runs on the
same diesel fuel as your main engine. The
diesel fuel is drawn through a separate
supply tube that is positioned in the tank in
a manner that will not allow the generator
to draw fuel and run if the tank level dips
below the
¼
level.
Depending on the ambient temperatures, the generator
may pre-heat prior to cranking. This pre-heat condition is
noted by flashing the light on the generator start switch
until the cycle is complete (up to 15 seconds). Once it has
pre-heated su
ffi
ciently, the starter will engage and the
engine will start.
BEFORE STARTING THE GENERATOR:
1. Turn o
ff
the air conditioners and any other large
electrical loads, as recommended by the generator
manufacturer.
2. If the generator previously ran out of fuel, add fuel to
the tank.
3. Prime the generator by holding the generator switch
in the stop position.
TO START THE GENERATOR:
1. Press and hold the generator start switch in the “Start/
Preheat” position. It will automatically delay and pre-
heat.
2. The indicator light will flash rapidly while pre-heating,
and the generator will crank and start.
3. When the generator starts, release the switch.
4. The indicator light will stay illuminated while the
generator is running.
TO STOP THE GENERATOR:
1. Press the generator switch in the “Stop” position.
2. Release the switch.
3. The indicator light will turn o
ff
when the generator
stops.
Service Required Indicator:
1. The generator switch indicator light may flash in a
series of three quick flashes, followed by a short
pause, and then quickly flash three more times. These
flashes indicate that service is required.
2. Refer to the owner’s manual for your specific
generator for more in-depth descriptions of flashing
codes.
CAUTION
!
Failure to turn o
ff
the 120 volt appliances when
starting or stopping the generator may damage the
transfer switch and/or electrical appliances.
Excessive cranking can damage the starter motor.
Do not crank the generator more than 30 seconds at
a time, and allow at least two minutes before trying
again if the first attempt fails.
IMPORTANT
!
If your coach contains an Energy Management System,
8kw generator, and three roof air conditioners, the
combined load may exceed the capabilities of the
generator. Please remember to turn o
ff
one of the air
conditioners as the 8kw generator is not intended to
run all three roof air conditioners at the same time.
NOTICE
!