© 2021 Copyright Newmar Corporation. All rights reserved. For the most up-to-date version of this content, and for more product-specific information, please refer to Newgle.
101
ELECTRICAL
TIME/DATE SCREEN
View and/or set the current time and date on the ATS. To
get to the TIME/DATE screen from the main screen, push
the front lever right or left repeatedly until you see the time
and date. To set, press the lever IN once quickly. You will
see a blinking cursor. Push the lever left until the cursor is
over the minutes digit.(Do not try to set the seconds - they
reset to zero.) Once you have the correct setting for the
minutes, continue on with setting the hour, date, month,
year and so on by pushing the lever to the left.
Once you have entered the correct time and date, press
and HOLD the lever IN for 3 seconds. You will see “TIME IS
SET” once complete. You can now release the lever.
When you are on the TIME DATE screen and the cursor
is not blinking, you can navigate to the other top level
screens such as the main screen, or the L1 volts screen, etc.
VIEW FAULTS SCREEN
This allows you to view the faults recorded whenever
the ATS detected a fault with electrical power. To view,
momentarily push the front lever DOWN or IN. The
screen will display fault 1, which is the most recent fault
that occurred and was detected by the ATS. The screen
will scroll through the following items for fault 1 every 3
seconds:
1.
MODE- State of ATS when fault occurred (MODE
SHORE = shore power; MODETGEN = transferring to
Gen power, etc.)
2.
FAULT CODE (L1 LO, L2 LO, etc.)
3.
L1/L2 Volts and Currents at the time of the fault.
4.
Frequency of Line 2
5.
Time of Fault
6.
Date of Fault
To see the next fault, push lever right, showing fault 2. Keep
pushing the lever right to see up to 50 faults. Pushing the
lever left goes backwards through the faults.
If no faults have occurred, you will still see fault number
headings, but the information will be zeroed out. Voltages/
currents will be zero, time will be 00:00:00 and date will be
00-00-00; or you may have only 5 faults and the other 45
fault numbers will be zeroed out as described, etc.
To exit the fault screens, push the lever DOWN/IN
momentarily, returning to VIEW FAULTS screen from which
you can navigate as previously described.
Source(s): Southwire Surge Guard Remote Power Control Monitor LCD
Display with Navigation Installation and Operating Instructions
Product(s): This source is associated with more than one product. Refer
to Newgle for more information about the product(s) o
ff
ered for your
coach’s model year.
Содержание VENTANA 2022
Страница 1: ...SM 2022...