94
| Command Line Reference | SmartNA-X 1G/10G Modular
SmartNA-X
™
1G/10G User Guide 1.4
©
2015 Network Critical Solutions Limited
Parameters
This command has no arguments or keywords.
Example
Report the system name:
CONTROLLER>
show name
NC-unit14 copper SFP+ mixed
set name
Use the
set name
command to enter a system name for the device installation.
Syntax
set name
name-info
Parameters
name-info
Specify a name for the system using 1-19 alphanumeric characters. Commas and other punctuation characters
may be used but may be replaced on RADIUS servers by underscores "_".
Example
Set name information to "Network Critical SmartNA-X":
CONTROLLER>
set name Network Critical SmartNA-X
CONTROLLER>
show name
Network Critical SmartNA-X
show location
Use the
show location
command to report location details (blank by default).
Syntax
show location
Parameters
This command has no arguments or keywords.
Example
Report location details:
CONTROLLER>
show location
boston_data-center rack32D
set location
Use the
set location
command to enter location information for the device installation.
Syntax
set location
location-info
Parameters
location-info
Specify location details using 1-19 alphanumeric characters. Commas and other punctuation characters may
be used but may be replaced on RADIUS servers by underscores "_".