![NetApp NearStore R100 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/netapp/nearstore-r100/nearstore-r100_hardware-and-service-manual_1669958009.webp)
Safety Information (Sicherheitshinweise)
ix
Safety Information (Sicherheitshinweise)
Safety rules
All products are Class 1 laser devices. You must follow these safety rules
when working with this equipment:
WARNING
WARNING
Failure to follow these directions could result in bodily harm or loss of
life.
◆
Switzerland only—for FAS900, GF900, R200, and C6200 systems:
This equipment relies on fuses/circuit breakers in the building installation
for overcurrent protection. Each power supply must receive power from a
separately dedicated outlet with a 10A fuse/circuit breaker.
◆
When installing disk shelves and a storage appliance into a movable
cabinet or rack, install from the bottom up for best stability.
◆
DC-based systems must be installed in a restricted access location and the
two input power terminals for the DC power supply must be connected to
separate isolated branch circuits.
◆
To reduce the risk of personal injury or equipment damage, allow internal
components time to cool before touching them and ensure that the
equipment is properly supported or braced when installing options.
◆
This equipment is designed for connection to a grounded outlet. The
grounding type plug is an important safety feature. To avoid the risk of
electrical shock or damage to the equipment, do not disable this feature.
◆
This equipment has one or more replaceable batteries. There is danger of
explosion if the battery is incorrectly replaced. Replace the battery only
with the same or equivalent type recommended by the manufacturer.
Dispose of used batteries according to the manufacturer’s instructions.
Warning for units with
multiple power cords
If your storage appliance or disk shelf has multiple power cords and you need
to turn the unit off, heed the following warning:
WARNING
WARNING
This unit has more than one power supply cord. To reduce the risk of
electrical shock, disconnect all power supply cords before servicing.
Содержание NearStore R100
Страница 6: ...vi Table of Contents...
Страница 20: ...10 Installation rules and restrictions...
Страница 54: ...44 Connecting an R100 chassis to an Ethernet network...
Страница 78: ...68 System messages at startup...
Страница 140: ...130 Replacing the CompactFlash unit subassembly...
Страница 164: ...154 Index...