![NetApp NearStore R100 Скачать руководство пользователя страница 151](http://html1.mh-extra.com/html/netapp/nearstore-r100/nearstore-r100_hardware-and-service-manual_1669958151.webp)
Chapter 9: Troubleshooting LCD Messages
141
All other error messages
About all other error
messages
These error messages might appear when the system is operating, when it has
halted, or when it is restarting because of system problems.
Error message
Explanation
Fatal?
Corrective action
Disk n is broken
n—The RAID group disk
number. The solution depends on
whether you have a hot spare in
the system.
No
See the Data ONTAP System
Administrator’s Guide for
information about how to
locate a disk based on the
RAID group disk number and
how to replace a faulty disk.
Fans stopped; replace
them
One of the fan subassemblies of
the chassis failed.
No
Replace the failed fan
subassembly as soon as
possible.
Backplane fans non-
functional
One of the fan subassemblies of
the chassis failed.
Yes
Replace the failed fan
subassembly immediately.
Power supply degraded
One of the power supply units is
turned off, was removed from
the chassis, or failed.
No
Verify that both power supplies
are installed and turned on. If
you still get this error, replace
the power supplies one at a
time to determine the failed
power supply.
Dumping core
The system is dumping core
after a system crash.
Yes
Write down the system crash
message on the system console
and report the problem to
Network Appliance Technical
Support.
Содержание NearStore R100
Страница 6: ...vi Table of Contents...
Страница 20: ...10 Installation rules and restrictions...
Страница 54: ...44 Connecting an R100 chassis to an Ethernet network...
Страница 78: ...68 System messages at startup...
Страница 140: ...130 Replacing the CompactFlash unit subassembly...
Страница 164: ...154 Index...