5
R100 component and environmental parameters
R100 chassis
Physical
characteristics
The following table lists the physical characteristics of the chassis.
Space requirements
The following table describes the recommended minimum clearance for the
chassis.
Electrical
requirements
The following table lists the AC power electrical requirements for the chassis.
Characteristics
U.S.
Metric
Height
8.75 in. or 5U, where 1U = 1.75 in.
22.2 cm
Width
17 in.
43.2 cm
Depth
25.25 in.
64.1 cm
Weight fully loaded
66 lbs
30 kg
Recommended minimum clearance
U.S.
Metric
Front clearance
9 in.
22.9 cm
Rear clearance
30 in.
76.2 cm
Clearance in vertical rack space above
chassis for rear vents
0.5 in.
3.81 cm
Condition
Requirement
AC power supply
100 to 240V AC single phase
Maximum rated current per
AC input
5A at 100 to 240V AC
Typical current per AC input
2.25A at 100V AC