Neomatica, LLC. Terminal ADM700 3G GLONASS/GPS. Ed. 7.2, dd. 24.11.2018
62
№
Command
Response
Parameters
Description
53
INSTATIC X
Example:
InStatic 3
Input X for static
Example:
Input 3 for static
X=0..5
– input number,
X=255
– function disabled,
Setting input number for Static navigation mode
activation. Command without parameter X
restores to the current setting. No input is set by
default for Static navigation mode activation.
54
STATICTOIN X
Example:
STATICTOIN 1
STATICTOIN X
Example:
STATICTOIN 1
X=0..5
– input number
X=255
– function disabled
Choosing of analogue input which data will be
being substituted by the transmission of
“coordinates freezing” state.
55
TEMPTOIN X
Example: TEMPTOIN 2
TEMP CONNECT TO INPUT X
Example: TEMP CONNECT
TO INPUT 2
X=0,..,5
– input number
X=255
— sensor is disabled
Setting of input number which data will be being
substituted by the transmission of inner
temperature sensor data.
56
MAXACC X
Example: MAXACC 9
MAX AAC=X
Example: MAX AAC=X
X=3,..,255
–conditional
vibration level.
Setting of vibration level below which the
coordinates are being frozen. Changing of this
parameter might cause improper tracker
operation.
57
SD
SD ON
SD OFF
The command allows to define if a memory card
in the device works well at valid settings.
58
CANDATA X
Example: CANDATA 1
CANDATA X
Example: CANDATA_1 = 1F
X
– tag number
Displaying of CAN tag value.