Neomatica, LLC. Terminal ADM700 3G GLONASS/GPS. Ed. 7.2, dd. 24.11.2018
58
№
Command
Response
Parameters
Description
32
INTRUEOUT Y,X,Z
Example:
InTrueOut 0,3,2
Input Y TrueOut X Mode Z
Пример:
Input 0 TrueOut 3 Mode 2
Y=0..5
– input number;
X=0...3
– output number;
Z=0
– output deactivated
Z=1
– output activated in
guard mode,
Z=2
– output always
activated
Binding output to the event in input.
33
InGuardMode X
Example:
InGuardMode 0
Input X on guard mode
Example:
Input 0 on guard mode
X=0..5
– input number
Setting the input number for guard mode
activation, the command without X parameters
restores to the current input number for guard
mode activation. No input is set by default for
guard mode activation.
34
InGuardModeClear
no input in guard mode
Clearing input number for the activated guard
mode.
35
ININFO Y
Пример:
ININFO 2
Example:
Input 2: InTrue 8000..15000,
InFalse 0..3000, InGuardMode
0, InTrueSms 2, SmsTxt
‘ALARM‘
X=0..5
– input number
Information displaying about input settings
36
Guard on
Guard On
Arming
37
Guard off
Guard Off
Disarming
38
Alarm Off
Alarm Off
Alarm deactivation