Neomatica, LLC. Terminal ADM700 3G GLONASS/GPS. Ed. 7.2, dd. 24.11.2018
68
№
Command
Response
Parameters
Description
88
CALLANSWERTIME X
Example: CALLANSWERTIME
30
CALLANSWERTIME X
Example: CALLANSWERTIME
30
X=0
– function disabled
X=1..255
– time in seconds
Installing answer timeout after which the
incoming call is rejected.
89
MAKECALLTIME X
Example: MAKECALLTIME 60
MAKECALLTIME X
Example: MAKECALLTIME 60
X=0
– function disabled
X=1..255
– time in seconds
Installing answer timeout after which the
outgoing call is rejected.
90
ADM20 X,Y,Z
Example: ADM20 2,1,6
ADM20[X] Y,Z ready
Example: ADM20[2] 1,6 ready
X=0..4 number; Y=address
on
can
bus
RS-485;
Z=operation mode
Setting of sequence number and operation
mode for ADM20 reader.
91
ADM20MODE X,Y,Z,A,B
Example:
ADM20MODE 0,2,0,2,0
ADM20MODE[X] Y,Z,A,B
enabled
Example: ADM20MODE[0]
2,n/a,2,n/a enabled
X=0..4
setting
reader
number; Y=0..2 setting mode
number; Z= card checking
period; A=0..5 analogue input
number; B=output number
Setting of chosen reader operation mode.
Setting card checking period, analogue input
choosing which data will be substituted by
transmission of card number/tag.
92
ADM20OUTMODE X,Y
Example:
ADM20OUTMODE 1,0
ADM20OUTMODE 0:0, 1:0,
2:0, 3:0, 4:0
Example: ADM20OUTMODE
0:1, 1:0, 2:0, 3:0, 4:0
X
— ADM20 reader number.
Y=0...1 the condition in which
tracker output will be when a
card is detected
Setting of tracker output condition when
detecting a card by ADM20 reader.
93
TACHOENABLED X,Y
Example:
TACHOENABLED 1,2
TACHOENABLED X,Y
Example:
TACHOENABLED 1,2
X=0 tachograph VDO; X=1
tachograph
SHTRICH-
М;
X=0 RS-232_0 port; Y=1
RS-232_1 port;
Y=2 RS-485 port.
Choosing type and port of the tachograph being
connected.