This interface shows some basic options for AOI equipment, as introduced in the following part:
Last Program Auto Load: prompting {Open the Previous Program} at startup
Auto_load PCB Model (Barcode Gun): different boards will be tested after matching the opened
program according to the barcode after scanning.
Open Multi PCB: used for collinear inspection of various PCB boards, and distinguished by ID Mark.
Do not view the inspect results: when meeting NG PCB during the test, if the user wants to display
NG on the screen but doesn't want the NG interface to pop up, the user can check [Do not View the
Inspect Results].
Use user-defined NG code: the system itself has set some NG codes for NG category, but it is usually
not applicable. The user should check [Use User-defined NG Code]
Safety Sensor Check: used to close and open the safety light curtain.
Do not View Group Info: in editing mode, if multiple groups are added to an inspection frame, the
system will pop up the images of each group at the bottom of the screen. If the user doesn't want to
pop up this window, check [Do not View Group Info].
Spilt display mode: used for displaying false alarms according to the arrangement sequence of spilts
when checking false alarms by BGA.
Many Barcode Mode NG Save: when each spilt of PCB has barcode, it can be stored according to
barcode of single spilt.
Rotate with the angle of mark point: whether the image of a single FOV rotates with the rotation
angle of Mark point.
Separate inspect: when checked, FOV photographing and inspection are separated, and it is not
necessary to wait for the inspection operation to be completed before taking the next image. At the
same time, there will be cases where the result will be produced after the operation is completed, such
as delay after the image of the whole PCB is taken.
Optimizing the Park of Double Track: this option is used by double-track AOI, and it is not necessary
to return to the park position for inspection when the front and rear tracks are switched, which can
speed up the inspection.
Save SPC NG Pictures with Search Size: when checked, SPC will save images with search range size.
Red Glue PCB: used when editing red glue board program.,After checking, the default inspection
option of bonding pad is [Glue Overflow], which speeds up the program.
No Wait Confirm Display: in inspection mode, if the user chooses not to wait for result confirmation,
and has not confirmed and closed NG result window in time, the next PCB result will not cover the
current unconfirmed result window under normal circumstances. But if the user wants subsequent
inspection results to cover the current result window in time, the user can check [No Wait Confirm
Display].
PCB Bad Mark Check: if users need to use skip area, they need to check the function "PCB Bad Mark
Check".
Only inspect the offset according to the standard: for the area method inspection frame, the user can