45
Click [FOV Component Positioning] or [Overall Positioning] if the inspection frame of
individual components is found to be incorrect after completion, The former is to position the
component frame inside the camera frame only according to the noumenon frame, while the
latter is to position the component frame on the whole PCB board according to the noumenon
frame, as shown in the following figure:
After positioning, click [File Management]-[Save] in the menu bar to complete the editing mode.
8.2.2 Debugging mode
Enter the inspection mode in [Working Mode]-[Inspection Mode]. As shown in the
following figure:
When debugging, check [Debug] and [Not Add Group], and then click [Start], as shown below:
[Space Key] is the shortcut key of the start key. If there is a board at the board entrance end, it
will automatically enter for inspection. After the inspection is completed, the false alarm
debugging interface will pop up. As shown in the following figure: