3
Chapter III Working Conditions of
Equipment
To avoid external factors affecting the normal use of this equipment, please follow the following
items:
3.1 Operating environment of this equipment:
The environment temperature of the equipment is: 10℃ to 35℃; the relative humidity
is:35% to 80%.
The equipment should be placed in a place free from direct sunlight, dew and splashing of
chemical liquids such as water and oil.
3.2 When the equipment is in normal use, please reserve a certain space in front of and behind
the equipment so as to facilitate the maintenance of the equipment and the emission of internal
heat. Do not cover the equipment with cover during its normal operation, so as not to affect the
heat emission.
3.3 Please keep the equipment in the following places when the equipment is not used:
Environment temperature: 0℃ to 40℃; relative humidity: 35% to 80%
The equipment should be placed in a place free from direct sunlight, dew and splashing of
chemical liquids such as water and oil.
To prevent dust, the equipment may be covered.
3.4 Impact or strong vibration should be avoided. Otherwise, the failure of equipment may be
caused.
3.5 When cutting off the power supply of the equipment, please perform the system
exit/shutdown process in the following order. If the power supply is directly cut off or restarted
without performing this process, the data will not be kept intact and the hard disk may also be
damaged.
The correct exit procedure is as follows:
Exit application program → Exit Windows → Cut off power supply
3.6 When the equipment is running, do not open the safety door of the equipment to avoid
accidents.
3.7 Repeated ON /OFF of the power supply will cause the failure of the main machine. After the
power supply is OFF, please restart the power supply after 20 seconds.
3.8 To prevent the PCB or equipment to be inspected from being damaged, please use the
substrate of inspection object conforming to the specifications and dimensions of the equipment.
It is necessary to note that the height requirements of the equipment for the parts of PCB are as
follows:
Height of front part of PCB inspection surface ≤ 30 mm
Height of back part of PCB inspection surface ≤50mm