CHAPTER 10 POWER MANAGEMENT UNIT (PMU)
User’s Manual U14272EJ3V0UM
196
10.5.2 Activation via CompactFlash interrupt request
When the CF_BUSY# signal is asserted, the PMU asserts the POWERON signal to provide an external
notification that the CPU core is being activated. After asserting the POWERON signal, the PMU checks the
BATTINH signal and then de-asserts the POWERON signal.
If the BATTINH signal is at high level, the PMU cancels peripheral unit reset and starts the Cold Reset sequence
to activate the CPU core.
If the BATTINH signal is at low level, the PMU sets 1 to the BATTINH bit in the PMUINTREG register and then
performs another shutdown. After the CPU core is restarted, the BATTINH bit must be checked and cleared to 0 by
software.
Figure 10-5. Activation via CompactFlash Interrupt Request (BATTINH = H)
BATTINH/BATTINT# (Input)
MPOWER (Output)
POWERON (Output)
CF_BUSY# (Input)
RTC (Internal)
H
Figure 10-6. Activation via CompactFlash Interrupt Request (BATTINH = L)
BATTINH/BATTINT# (Input)
MPOWER (Output)
L
L
POWERON (Output)
CF_BUSY# (Input)
RTC (Internal)