Maintenance and Troubleshooting 4-13
UPS Battery Replacement
The battery in the UPS is automatically recharged and lasts a long time. When the battery
starts to reach end-of-life, the Check Battery lamp lights, indicating that the battery should
be replaced within four weeks. Use the following procedures to replace the battery.
Remove power from the UPS and all connected devices.
1.
Turn off the power switch on the UPS and on all connected devices.
2.
Unplug the UPS from the wall socket.
3.
Unplug all devices from the UPS.
Use the following procedure to remove the battery cover.
1.
Turn the UPS over.
2.
Press down firmly on the two cover release tabs while pushing the cover outward.
3.
Remove the cover from the UPS.
Figure 4-5 Removing the Battery Cover