CHAPTER 9 TROUBLESHOOTING
User’s Manual U17454EJ1V0UM
73
9.2 Trouble During Operation (Main Unit)
(1) When the FPL3 is connected to the personal computer but the Power LED is not turned on.
Cause:
The FPL3 or the USB port of the personal computer may be damaged.
Action:
Try a connection to another personal computer.
(2) The Status LED is turned on when the FPL3 is not communicating with the target device.
In accordance with the specifications of the FPL3, the Status LED may turn on even if the FPL3 is not
communicating with the target device.
The Status LED is designated to blink during communication with the target device.
(3) The “Add New Hardware Wizard” screen is displayed when the FPL3 is connected with a personal computer.
Cause:
If the USB connector of the FPL3 is not inserted into the USB port during installation but into another USB
port, the FPL3 may be recognized as a new hardware item.
Action:
Install the driver by referring to 3.2 Driver Installation.