CHAPTER 4 OPERATION USING GUI SOFTWARE
User’s Manual U17454EJ1V0UM
44
(3) [Program] command
The [Program] command transmits the specified user program to the target device and writes them to
the flash memory.
After execution of the [Program] command, verification to detect a communication error of the user program
from the FPL3 to the target device is executed in accordance with the setting of ‘Command options’ on the
Advance tab of the [Device] > [Setup…] menu.
While programming is in progress, the progress is displayed in the action log window, indicating the operation
of the programmer. This progress indicates the progress of programming the target device as a percentage.
After completing the [Program] command, the GUI software displays the target device command execution
result.
(4) [Verify] command
The [Verify] command transmits the specified user program to the target device connected to the
FPL3 and verifies the data written to the flash memory of the target device.
While verification is in progress, the progress is displayed in the action log window, indicating the
operation of the programmer. This progress indicates the progress of verifying the target device as a
percentage.
After completing the [Verify] command, the GUI software displays the target device command execution result.
(5) [Security] command
The [Security] command initiates the programming of the security flag of the target device connected to the
FPL3. Set ‘Security flag settings’ on the Advance tab of the [Device] > [Setup…] menu.
(6) [CheckSum] command
The [CheckSum] command initiates the reading of the checksum values of the target device connected to the
FPL3. This value differs from the value displayed in the parameter window in the main window.
(7) [Autoprocedure (EPV)] menu
The [Autoprocedure (EPV)] command sequentially executes the [Erase] and [Program] commands
explained above.
After execution of the [Autoprocedure (EPV)] command, to verify the checksum values of the data written to the
flash memory of the target device and the program file to detect a communication error of the user program
while it is being transmitted, specify automatic execution of the [CheckSum] command after execution of the
[Program] command, using the Command options on the Advance tab of the [Device] > [Setup…] menu.
During EPV, the progress status of the programmer operation is displayed in the action log window. Refer to
CHAPTER 5 USAGE EXAMPLE for the selected command, and its execution operation and message.
After completing the [Autoprocedure (EPV)] command, the GUI software displays the target device command
execution result.
(8) [Signature read] command
The [Signature read] command reads the target signature information (such as device name and flash memory
information).