User’s Manual U17454EJ1V0UM
56
CHAPTER 5 USAGE EXAMPLE
This chapter explains a series of basic operations of the FPL3 with the GUI software, taking a case where the
µ
PD78F0533 is used as the target device as an example. This chapter covers how to start the system, execute the
[Autoprocedure (EPV)] command, and program the target device.
Refer to CHAPTER 4 OPERATION USING GUI SOFTWARE for the other commands and applications.
The conditions of the series of operations described in this chapter are as follows.
•
Target system
Target device:
µ
PD78F0533
Voltage level:
5 V
Communication: UART
•
FPL3
Parameter file:
78F0533.PRM
Clock setting:
16 MHz
Port:
COM5 (115,200 bps)
MODE switch:
3 (V
DD
: 5 V, CLK: 16 MHz)
Operation mode:
Chip
Write HEX:
FPL3_TEST.HEX
Option setting:
Blank check before Erase
Read Verify after Program
(1) Installing the GUI software
Install the FPL3 GUI software in the host machine you are using, by referring to CHAPTER 3 SOFTWARE
INSTALLATION (if the software has not been installed yet).
(2) Installing the driver
Install the USB driver in the host machine you are using, by referring to CHAPTER 3 SOFTWARE
INSTALLATION (if the driver has not been installed yet).
(3) Installing the parameter file
Copy the parameter file for the
µ
PD78F0533 to the hard disk and install it in <FPL3-installation-path>\PRM.
Download the parameter file from the following:
http://www.necel.com/micro/ods/eng/index.html (website in English)
http://www.necel.com/micro/ods/jpn/index.html (website in Japanese)