5. Checking the Duplicating Operation of Modules
Express5800/R320d-E4, R320d-M4 Maintenance Guide (VMware 5.5)
45
Chapter 1 Maintenance
4.
Start the I/O module stopped in step 3.
Run the following command to start the stopped I/O module 0.
When the I/O module is started, diagnosis of I/O module, and duplication of I/O module are
performed.
The status LED of I/O module changes as shown below:
[Indications of status LED]
Immediately after the I/O module startup until the completion of diagnosis:
LED
I/O module 0
I/O module 1
(1)
PRIMARY LED
–
Green
(2)
DISK ACCESS LED
–
Amber or Green blinking
(Green when accessing to
HDD)
LED
System
(3)
System FT LED
–
When duplication of disks is started after the completion of diagnosis of I/O module:
LED
I/O module 0
I/O module 1
(1)
PRIMARY LED
–
Green
(2)
DISK ACCESS LED
Amber or Green blinking
(Green when accessing to
HDD)
Amber or Green blinking
(Green when accessing to
HDD)
LED
System
(3)
System FT LED
–
After the completion of disk duplication and when the I/O modules are duplicated:
LED
I/O module 0
I/O module 1
(1)
PRIMARY LED
–
Green
(2)
DISK ACCESS LED
Green
Green
LED
System
(3)
System FT LED
Green
# cd /opt/ft/bin
# ./ftsmaint bringup 10