4. Maintenance of Express5800/ft series
Express5800/R320d-E4, R320d-M4 Maintenance Guide (VMware 5.5)
40
Chapter 1 Maintenance
(4) Diagnosis is performed when CPU module 1 is started. The new BIOS is applied to CPU module
1 from CPU module 0 automatically, and duplication process is performed.
# /opt/ft/bin/ftsmaint bringUp 1
Completed bringUp on the device at path 1.
Important Do not operate the machine and power supply unit while the firmware is updated.
The firmware is destroyed and modules may need to be replaced.
5. Run the following command to check that Op State of CPU module shows "DUPLEX" and Firmware Rev
shows the new BIOS version.
# /opt/ft/bin/ftsmaint ls 0
Op State
: DUPLEX
:
Firmware Rev
: BIOS Version 7.0:27
Version is indicated in the underlined part.
# /opt/ft/bin/ftsmaint ls 1
Op State
: DUPLEX
:
Firmware Rev
: BIOS Version 7.0:27
Version is indicated in the underlined part.
6. Unmount ft control software Install DVD, if mounted. Then, disconnect the DVD drive.