3-14 Setting Up Your Server
Positioning of Cooling Kit
Adjust the position of the cooling kit.
IMPORTANT:
If you are going to install the inner rails on both sides of the server,
be sure to adjust the position of cooling kit properly. Otherwise, a
failure of the server, a personal injury, a fire, and/or a damage to the
surroundings may be caused.
The cooling kit is unable to be removed. Adjust the position
according to the explanation below.
Make sure the cooling kit is surely locked after positioning.
Fully extend the outer rail, and move the cooling kit while pressing the spring at center of the kit.
Adjust the position of the cooling kit according to rack size.
The adjustment position of cooling kit is marked on the rear face of rail assembly.
No.
Space between mount angles on rack
B1
Adjustment position of cooling kit when inner rails are installed on one side
0
790 mm
A1
740 mm to 789 mm
A2
706 mm to 739 mm
A3
672 mm to 705 mm
A4
640 mm to 671 mm
A5
620 mm to 639 mm
Cooling kit
Press the spring.
Содержание N8100-1573F
Страница 16: ...x This page is intentionally left blank...
Страница 19: ...Notes on Using Your Server 1 3 3 5 inch Disk Model FRONT REAR...
Страница 126: ...4 50 Configuring Your Server This page is intentionally left blank...
Страница 202: ...6 8 Installing and Using Utilities 4 Click Parameter File Creator Parameter File Creator will appear...
Страница 296: ...A 2 Specifications This page is intentionally left blank...
Страница 304: ...C 2 IRQ This page is intentionally left blank...
Страница 333: ...Installing Windows Server 2008 D 29 4 Activate Windows The Windows activation is complete...
Страница 390: ...G 2 Using a Client Computer Which Has a CD Drive This page is intentionally left blank...
Страница 394: ...H 4 Product Configuration Record Table This page is intentionally left blank...