CHAPTER 10 SERIAL INTERFACE UART6
Preliminary User’s Manual U19014EJ1V0UD
227
10.3 Registers Controlling Serial Interface UART6
Serial interface UART6 is controlled by the following seven registers.
•
Asynchronous serial interface operation mode register 6 (ASIM6)
•
Asynchronous serial interface reception error status register 6 (ASIS6)
•
Asynchronous serial interface transmission status register 6 (ASIF6)
•
Clock selection register 6 (CKSR6)
•
Baud rate generator control register 6 (BRGC6)
•
Port mode register 1 (PM1)
•
Port register 1 (P1)
(1) Asynchronous serial interface operation mode register 6 (ASIM6)
This 8-bit register controls the serial communication operations of serial interface UART6.
This register can be set by a 1-bit or 8-bit memory manipulation instruction.
Reset signal generation sets this register to 01H.
Remark
ASIM6 can be refreshed (the same value is written) by software during a communication operation
(when bit 7 (POWER6) and bit 6 (TXE6) of ASIM6 = 1 or bit 7 (POWER6) and bit 5 (RXE6) of ASIM6
= 1).
Figure 10-2. Format of Asynchronous Serial Interface Operation Mode Register 6 (ASIM6) (1/2)
Address: FF50H After reset: 01H R/W
Symbol
<7>
<6>
<5>
4 3 2 1 0
ASIM6 POWER6 TXE6
RXE6
PS61
PS60
CL6
SL6
ISRM6
POWER6
Enables/disables
operation of internal operation clock
0
Note 1
Disables operation of the internal operation clock (fixes the clock to low level) and asynchronously
resets the internal circuit
Note 2
.
1
Enables operation of the internal operation clock
TXE6
Enables/disables
transmission
0
Disables
transmission
(synchronously resets the transmission circuit).
1
Enables
transmission
RXE6
Enables/disables
reception
0
Disables
reception
(synchronously resets the reception circuit).
1
Enables
reception
Notes 1.
The output of the T
X
D6 pin goes high level and the input from the R
X
D6 pin is fixed to the high level
when POWER6 = 0 during transmission.
2.
Asynchronous serial interface reception error status register 6 (ASIS6), asynchronous serial interface
transmission status register 6 (ASIF6), and receive buffer register 6 (RXB6) are reset.