CHAPTER 6 16-BIT TIMER/EVENT COUNTER 00
Preliminary User’s Manual U19014EJ1V0UD
171
Figure 6-52. Example of Software Processing for Pulse Width Measurement (2/2)
<2> Capture trigger input flow
Edge detection of TI000, TI010 pins
Calculated pulse width
from capture value
Stores count value to
CR000, CR010 registers
Generates capture interrupt
Note
TMC003, TMC002 bits =
01 or 10
Register initial setting
PRM00 register,
CRC00 register,
port setting
Initial setting of these registers is performed
before setting the TMC003 and TMC002 bits.
Starts count operation
START
<1> Count operation start flow
TMC003, TMC002 bits = 00
The counter is initialized and counting is stopped
by clearing the TMC003 and TMC002 bits to 00.
STOP
<3> Count operation stop flow
Note
The capture interrupt signal (INTTM000) is not generated when the reverse-phase edge of the TI000 pin
input is selected to the valid edge of CR000.