CHAPTER 6 16-BIT TIMER/EVENT COUNTER 00
Preliminary User’s Manual U19014EJ1V0UD
126
Figure 6-13. Example of Register Settings for Interval Timer Operation
(a) 16-bit timer mode control register 00 (TMC00)
0
0
0
0
1
1
0
0
TMC003 TMC002 TMC001
OVF00
Clears and starts on match
between TM00 and CR000.
(b) Capture/compare control register 00 (CRC00)
0
0
0
0
0
0
0
0
CRC002 CRC001 CRC000
CR000 used as
compare register
(c) 16-bit timer output control register 00 (TOC00)
0
0
0
0
0
LVR00
LVS00
TOC004
OSPE00
OSPT00
TOC001
TOE00
0
0
0
(d) Prescaler mode register 00 (PRM00)
0
0
0
0
0
3
2
PRM001
PRM000
ES101
ES100
ES001
ES000
Selects count clock
0
0/1
0/1
(e) 16-bit timer counter 00 (TM00)
By reading TM00, the count value can be read.
(f) 16-bit capture/compare register 000 (CR000)
If M is set to CR000, the interval time is as follows.
•
Interval time = (M + 1)
×
Count clock cycle
Setting CR000 to 0000H is prohibited.
(g) 16-bit capture/compare register 010 (CR010)
Usually, CR010 is not used for the interval timer function. However, a compare match interrupt (INTTM010)
is generated when the set value of CR010 matches the value of TM00.
Therefore, mask the interrupt request by using the interrupt mask flag (TMMK010).