CHAPTER 6 16-BIT TIMER/EVENT COUNTER 00
Preliminary User’s Manual U19014EJ1V0UD
169
Figure 6-51. Example of Register Settings for Pulse Width Measurement (2/2)
(e) 16-bit timer counter 00 (TM00)
By reading TM00, the count value can be read.
(f) 16-bit capture/compare register 000 (CR000)
This register is used as a capture register. Either the TI000 or TI010 pin is selected as a capture trigger.
When a specified edge of the capture trigger is detected, the count value of TM00 is stored in CR000.
(g) 16-bit capture/compare register 010 (CR010)
This register is used as a capture register. The signal input to the TI000 pin is used as a capture trigger.
When the capture trigger is detected, the count value of TM00 is stored in CR010.