CHAPTER 13 SERIAL INTERFACE UART0
Preliminary User’s Manual U16315EJ1V0UD
255
PS01
PS00
Transmission operation
Reception operation
0
0
Does not output parity bit.
Reception without parity
0
1
Outputs 0 parity.
Reception as 0 parity
Note
1
0
Outputs odd parity.
Judges as odd parity.
1
1
Outputs even parity.
Judges as even parity.
CL0
Specifies character length of transmit/receive data
0
Character length of data = 7 bits
1
Character length of data = 8 bits
SL0
Specifies number of stop bits of transmit data
0
Number of stop bits = 1
1
Number of stop bits = 2
Note
If “reception as 0 parity” is selected, the parity is not judged. Therefore, bit 2 (PE0) of asynchronous serial
interface reception error status register 0 (ASIS0) is not set and the error interrupt does not occur.
Cautions 1. Clear the TXE0 and RXE0 bits to 0 before rewriting the PS01, PS00, and CL0 bits.
2. Make sure that TXE0 = 0 when rewriting the SL0 bit. Reception is always performed with
“number of stop bits = 1”, and therefore, is not affected by the set value of the SL0 bit.