CHAPTER 8 8-BIT TIMERS H0 AND H1
Preliminary User’s Manual U16315EJ1V0UD
193
Figure 8-9. Operation Timing in PWM Pulse Generator Mode (3/4)
(d) Operation when CMP0n = 01H, CMP1n = 00H
Count clock
8-bit timer counter Hn
CMP0n
TMHEn
INTTMHn
TOHn
(TOLEVn = 0)
01H
00H
01H 00H 01H 00H
00H 01H 00H 01H
CMP1n
00H
Remark