CHAPTER 13 SERIAL INTERFACE UART0
Preliminary User’s Manual U16315EJ1V0UD
256
(b) Asynchronous serial interface reception error status register 0 (ASIS0)
This register indicates an error status on completion of reception by serial interface UART0. It includes three
error flag bits (PE0, FE0, OVE0).
This register can be set by an 8-bit memory manipulation instruction and is read-only.
RESET input clears this register to 00H if bit 7 (POWER0) and bit 5 (RXE0) of ASIM0 = 0. 00H is read when
this register is read.
Address: FF73H After reset: 00H R
Symbol
7
6
5
4
3
2
1
0
ASIS0
0
0
0
0
0
PE0
FE0
OVE0
PE0
Status flag indicating parity error
0
If POWER0 = 0 and RXE0 = 0, or if ASIS0 register is read.
1
If the parity of transmit data does not match the parity bit on completion of reception.
FE0
Status flag indicating framing error
0
If POWER0 = 0 and RXE0 = 0, or if ASIS0 register is read.
1
If the stop bit is not detected on completion of reception.
OVE0
Status flag indicating overrun error
0
If POWER0 = 0 and RXE0 = 0, or if ASIS0 register is read.
1
If receive data is set to the RXB register and the next reception operation is completed before the
data is read.
Cautions 1. The operation of the PE0 bit differs depending on the set values of the PS01 and PS00 bits of
asynchronous serial interface operation mode register 0 (ASIM0).
2. Only the first bit of the receive data is checked as the stop bit, regardless of the number of
stop bits.
3. If an overrun error occurs, the next receive data is not written to receive buffer register 0
(RXB0) but discarded.
4. If data is read from ASIS0, a wait cycle is generated. Do not read data from ASIS0 when the
CPU is operating on the subsystem clock and the X1 input clock is stopped. For details, refer
to CHAPTER 29 CAUTIONS FOR WAIT.