CHAPTER 5 CLOCK GENERATOR
Preliminary User’s Manual U16315EJ1V0UD
126
5.8.3 Switching from X1 input clock to subsystem clock
Figure 5-16. Switching from X1 Input Clock to Subsystem Clock (Flowchart)
MCS = 1 not changed.
CLS is changed from 0 to 1.
; Subsystem clock operation
Subsystem clock operation
; X1 oscillation
; X1 input clock or Ring-OSC clock
; X1 input clock operation
PCC.7 (MCC) = 0
PCC.4 (CSS) = 0
MCM = 03H
CSS
←
1
Register setting
in X1 input
clock operation
X1 input
clock operation
Subsystem
clock