CHAPTER 27 ELECTRICAL SPECIFICATIONS (TARGET VALUES)
Preliminary User’s Manual U16315EJ1V0UD
416
AC Characteristics
(1) Basic operation
(T
A
=
−−−−
40 to +85
°°°°
C, 2.7 V
≤≤≤≤
V
DD
= EV
DD
≤≤≤≤
5.5 V, 2.7 V
≤≤≤≤
AV
REF
≤≤≤≤
V
DD
, V
SS
= EV
SS
= AV
SS
= 0 V)
Parameter
Symbol
Conditions
MIN.
TYP.
MAX.
Unit
3.3 V
≤
V
DD
≤
5.5 V 0.238
16
µ
s
Note 1
2.7 V
≤
V
DD
< 3.3 V
0.4
16
µ
s
4.0 V
≤
V
DD
≤
5.5 V
0.2
16
µ
s
3.3 V
≤
V
DD
< 4.0 V 0.238
16
µ
s
X1 input
clock
Note 2
2.7 V
≤
V
DD
< 3.3 V
0.4
16
µ
s
Main
system
clock
operation
Ring-OSC clock
4.17
8.33
16.67
µ
s
Instruction cycle (minimum
instruction execution time)
T
CY
Subsystem clock operation
114
122
125
µ
s
4.0 V
≤
V
DD
≤
5.5 V
2/f
sam
+
0.1
Note 3
µ
s
TI000, TI010 input high-level
width, low-level width
t
TIH0
,
t
TIL0
2.7 V
≤
V
DD
< 4.0 V
2/f
sam
+
0.2
Note 3
µ
s
4.0 V
≤
V
DD
≤
5.5 V
10
TI50, TI51 input frequency
f
TI5
2.7 V
≤
V
DD
< 4.0 V
5
MHz
4.0 V
≤
V
DD
≤
5.5 V
50
ns
TI50, TI51 input high-level width,
low-level width
t
TIH5
,
t
TIL5
2.7 V
≤
V
DD
< 4.0 V
100
ns
Interrupt input high-level width,
low-level width
t
INTH
,
t
INTL
1
µ
s
4.0 V
≤
V
DD
≤
5.5 V
50
ns
Key return input low-level width
t
KR
2.7 V
≤
V
DD
< 4.0 V
100
ns
RESET low-level width
t
RST
10
µ
s
Notes 1.
When the REGC pin is connected to V
SS
via a 0.1
µ
F capacitor.
2.
When the REGC pin is directly connected to V
DD
.
3.
Selection of f
sam
= f
XP
, f
XP
/4, f
XP
/256 is possible using bits 0 and 1 (PRM000, PRM001) of prescaler mode
register 00 (PRM00). Note that when selecting the TI000 or TI010 valid edge as the count clock, f
sam
= f
XP.
Содержание 78K0/KD1 Series