Operating instruction: O003 / 5759
Edition: 04/2019
Reproduction, duplication of this document - even a partial form –
are subject to our permission. All rights reserved.
In this data sheet any liability for changes, errors or misprints is excluded.
33
bzw.
The successful programming will be confirmed by the PC-program.
A2 format of the belt-type list
<Art-Nr.>
<Band-Typ>
<AdV-0>
<Soll-HPO>
<Soll-HPU>
<Presszeit>
100000
Band1/140°/2min
1
140
140
120
200000
Band2/150°/2min
1
150
150
120
300000
Band3/160°/2min
1
160
160
120
400000
Band4/170°/2min
1
170
170
120
500000
Band5/180°/2min
1
180
180
120
600000
Band6/190°/2min
1
190
190
120
The list on the belt types can be generated using optionally a spreadsheet program according to the
figure above. The file has to be subsequently saved in *.csv or *.txt format with separators [Tab].
The individual columns mean the following:
<Item number>
6-digit number, item number of the belt type
<Belt-type>
Designation of the belt type, 16 figures maximum
<AdV-0>
<AdV-1>
Maximum 3 different kinds of splicing can be defined for each belt type.
<AdV-2>
The kind of splicing is given by a 2 digit number. In the case less than 3
kinds of splicing are available for a belt type, the relevant columns are
remaining empty.
<Soll-HPtop>
Set temperature of the top heating plate for the correspondent splice type.
The input is made in [C°]
<Soll-HPbot>
Set temperature of the bottom heating plate for the correspondent splice
type. The input is made in [°C]
<Pressing power>
Hold-down time in [s] for the correspondent splice type