Operating instruction: O003 / 5759
Edition: 04/2019
Reproduction, duplication of this document - even a partial form –
are subject to our permission. All rights reserved.
In this data sheet any liability for changes, errors or misprints is excluded.
23
Set-up a new belt-type
The HPS 2 can store up to 2048 different belt-types.
To select a new belt-type the appropriate menu must be opened.
With this menu a user defined belt-type can be issued like the above mentioned procedure. Before
the selected belt type is going to be saved into the internal belt-type list of the device, it will be
proved if there already exists a belt-type with the same item number. In case of this, there will ap-
pear the information on the screen and the user can decide, whether the entry will be overwritten or
not.
< Belt-type >
< Press-type >
< Belt type new >
End
This menu point can be switched off with the HPS 2-
configuration program.
or
Item number.: ??????
Belt type user
Insert the 6-digit item no. with the
numerical keys
Insert the set temperature „top“ with
the numerical keys.
Item number.: 123456
Belt type user
Settemp. Hpl top
180°C
Settemp. Hpl bot
170°C
Insert the set temperature „bottom“ with
the numerical keys.
Hold-down time
0100 s
Save ?
OK=yes ESC=no
Belt type user
saved ! OK
Overwrite ?
OK=yes ESC=no
Hold-down time
Set invalid !
Settemp. Hpl bot
Set invalid !
Settemp. Hpl top
Set invalid !
Insert the hold-down time with
the numerical keys.
If the adjustment is out of
the allowed value
If the adjustment is out of
the allowed value
If the adjustment is out of
the allowed value
if the belt type with chosen item
number is already existing
End