ATP Tools and Materials
– continued
PRELIMINARY
SC
t
300 BTS Hardware Installation, ATP and FRU Procedures
DEC 2000
1-18
9–pin D (female)
9–pin D (female)
GND 5
5 GND
RX 3
3 RX
TX 2
2 TX
RTS 7
7 RTS
RSD/DCD 1
1 RSD/DCD
DTR 4
4 DTR
DSR 6
6 DSR
Figure 1-8: RS232–IEEE488 Converter Serial Cable Configuration
CTS 8
8 CTS
ON BOTH CONNECTORS SHORT
PINS 7 AND 8;
SHORT PINS 1, 4 AND 6
Communications Test Set w/JCDMA PCMCIA Card
This procedure requires one of the following test sets:
S
Motorola CyberTest
S
Advantest R3465 and HP 437B or Gigatronics 8541C Power Meter
S
Hewlett–Packard HP 8935
S
Hewlett–Packard HP8921 (w/CDMA and PCS interface for 1.7/1.9
GHz) and HP 437B or Gigatronics Power Meter.
S
RF power meter (average and code domain)
S
RF signal generator (capable of CDMA modulation)
S
Spectrum Analyzer
S
CDMA code domain analyzer
As of the writing of this manual, the Advantest CDMA
communications test set is the ONLY CDMA analyzer
approved by Motorola for automated BTS testing.
NOTE
GPIB cables
Two Hewlett Packard 10833A or equivalent; 1 or 2 meters long used to
interconnect test equipment and LMF terminal.
Power meter
This procedure requires one of the following power meters:
S
Gigatronics Model 8541C with 80601A power sensor capable of
measuring from –70 dBm to +23 dBm; supported by the LMF to
perform BTS Total Power measurement.
1