background image

Cabling Overview

DEC 2000

5-1

SC

t

300 BTS Hardware Installation, ATP and FRU Procedures

PRELIMINARY

Overview

This chapter provides the procedures to prepare the BTS site cabling for
sites equipped with the optional Primary Surge Suppressor.  Chapter 6
shows the scope of work for unit cabling.

You will connect the cables to the site and route them to the location of
the BTS.  You will attach the cables to the unit during the unit cabling
procedures in Chapter 6.

Repeat cabling installation as necessary for each unit at the BTS.

Cabling is one of the most noticeable aspects of
workmanship. Straight runs and proper turns are critical for
a positive evaluation of the work.

NOTE

Configurations Supported

This chapter supports cable installation for single carrier omni
configurations and multi–carrier omni configurations.  This chapter
supports cable installations for sites equipped with the optional Primary
Surge Suppressor.

Cabling Installation Order

To install the cables, Motorola recommends that the following
procedures be completed in the order shown:

1. Earth ground cabling

2. AC power cabling

3. DC power cabling

4. Battery cabling (optional)

5. Antenna cabling

6. Site I/O interface cabling

7. RGPS/HSO cabling (optional)

8. Span line daisy chain cabling (optional)

Cable Labels

The “Cable Descriptions and Part Numbers” in Table 4-1 provides cable
descriptions and part numbers.  The labels used to designate the cables
(A, B, C, etc.) are used throughout this manual.

5

Содержание SC 300

Страница 1: ...SCt300 BTS Hardware Installation ATP and FRU Procedures Software Release 2 15 x x SCt300 CDMA English DEC 2000 68P09224A55 1 PRELIMINARY ...

Страница 2: ...tion manual may not be copied reproduced distributed merged or modified in any manner without the express written permission of Motorola Furthermore the purchase of Motorola products shall not be deemed to grant either directly or by implication estoppel or otherwise any license under the copyrights patents or patent applications of Motorola as arises by operation of law in the sale of a product U...

Страница 3: ... Tools and Materials 1 21 Unit Identification 1 22 Installation and ATP Order 1 32 Chapter 2 Site Preparation Site Preparation Overview 2 1 Site Inspections 2 2 Prepare Site for the Arrival of the Equipment 2 6 Dimensions and Clearances 2 8 Chapter 3 Installing Mounting Bracket and Remote GPS Overview 3 1 Unpacking the Equipment and Inspecting for Damage 3 2 Attaching the Mounting Bracket to a Wal...

Страница 4: ...al Primary Surge Suppressor 5 2 Attaching Surge Suppressor to Mounting Bracket 5 10 Power Ground and Battery Cabling for Sites Equipped With Optional Primary Surge Suppressor 5 12 Antenna Cabling for Sites Equipped With Optional Primary Surge Suppressor 5 18 Site I O Span Line RGPS and Modem Cabling for Sites Equipped With Primary Surge Suppressor 5 24 RGPS Cabling for Multi BTS Configurations Equ...

Страница 5: ...ional Acceptance Test Procedures ATP ATP Overview 7 1 BTS Preparation 7 2 Test Equipment and LMF Connection 7 7 BTS Configuration 7 15 BTS Software 7 24 Test Equipment Setup 7 29 Test Equipment Selection 7 37 Power Meter Calibration 7 38 Test Cable Calibration 7 39 Create CAL File 7 42 RF Path Audit 7 44 Acceptance Tests 7 46 CDMA Operating Frequency Programming Information North American PCS Band...

Страница 6: ... Replaceable Unit FRU Procedures Field Replaceable Unit FRU Overview 9 1 Shut Down Restoring BTS Signaling 9 4 Site I O Junction Box Replacement Procedure 9 13 Short Duration Battery Replacement Procedures 9 16 Remote GPS Replacement Procedures 9 19 Full Unit Replacement Procedures 9 21 Appendix A Outdoor Grounding Guidelines Overview Outdoor Grounding Guidelines Summary A 1 Index ...

Страница 7: ...s 1 23 Figure 1 11 Microcell and Picocell Unit 1 24 Figure 1 12 Site I O Junction Box and Cable 1 24 Figure 1 13 Primary Surge Suppressor Optional 1 25 Figure 1 14 AC Installation Box Optional 1 25 Figure 1 15 Mounting Bracket for both Microcell and Primary Surge Suppressor 1 26 Figure 1 16 Mounting Bracket for Picocell 1 26 Figure 1 17 Adapters for Rack Mounting 1 27 Figure 1 18 Adapters for Pole...

Страница 8: ...uring Mounting Bracket to the Adapter 3 11 Figure 3 5 Pole Adapter and Straps 3 14 Figure 3 6 Attaching Mounting Bracket to a Pole 3 15 Figure 3 7 Attaching the Mounting Bracket to a Rack 3 18 Figure 3 8 Attaching MicroCell Back Solar Cover to Mounting Bracket 3 20 Figure 3 9 Installing the Remote GPS Head 3 22 Figure 4 1 Site Cabling for One Microcell 4 8 Figure 4 2 Site Cabling for Two Microcell...

Страница 9: ...ut Cable Connector Information 5 14 Figure 5 12 Primary Surge Suppressor AC Input Power Connection Locations 5 16 Figure 5 14 Antenna Cabling Details 5 18 Figure 5 15 Antenna Cabling for one Microcell with Primary Surge Suppressor 5 19 Figure 5 16 Antenna Cabling for Two Microcells with Primary Surge Suppressor 5 20 Figure 5 17 Antenna Cabling for Three Microcells with Primary Surge Suppressor 5 2...

Страница 10: ...6 17 Antenna Cabling for Two Microcells 6 27 Figure 6 18 Antenna Cabling for Three Microcells 6 27 Figure 6 19 Antenna Cabling for Four Microcells 6 28 Figure 6 20 Antenna Cabling for Two Picocells 6 28 Figure 6 21 Antenna Cabling for Three Picocells 6 29 Figure 6 22 Antenna Cabling for Four Picocells 6 29 Figure 6 23 Installation of Third and Fourth Antenna Lightning Arrestors 6 31 Figure 6 24 An...

Страница 11: ...e 7 8 15 Pin MMI LMF Serial Connector 7 8 Figure 7 9 R3465 Communications Test Set Timing Signal Detail Advantest R3465 7 11 Figure 7 10 Communications Test Set Timing Signal Detail CyberTest HP 8935 HP 8921 7 12 Figure 7 11 LMF to Test Equipment Connection 7 13 Figure 7 12 RS232 IEEE488 Converter Serial Cable Configuration 7 14 Figure 7 13 Power Meter Detail 7 35 Figure 7 14 Cable Calibration Tes...

Страница 12: ...List of Figures continued PRELIMINARY SCt300 BTS Hardware Installation ATP and FRU Procedures DEC 2000 x Figure 9 7 Unit Replacement MicroCell shown 9 24 ...

Страница 13: ...Mounting Bracket Installation 3 6 Table 3 3 Procedure to Secure the Mounting Bracket to a Wall 3 7 Table 3 4 Tools and Materials for Concrete Ceiling 3 10 Table 3 5 Procedure to Secure the Mounting Bracket to the Adapter 3 11 Table 3 6 Tools and Materials for Pole Mounting 3 12 Table 3 7 Procedure for Attaching the Mounting Bracket to a Pole 3 13 Table 3 8 Tools and Materials for Rack Mounting 3 1...

Страница 14: ...quired for Outdoor Installations 4 19 Table 4 20 AC Installation Box Cabling 4 19 Table 4 21 Procedure to Install DC Input Cable s 4 20 Table 4 24 Cables Needed for Antenna Connections 4 21 Table 4 25 Pin and Signal Information for Cable C Antenna Cable 4 21 Table 4 26 Cables Needed for Antenna Connections 4 24 Table 4 27 Pin Signal Information for Site I O Cable 4 26 Table 4 28 Connecting the RGP...

Страница 15: ...5 37 Table 5 21 Cable Run List for Span Line Daisy Chain Cabling 5 39 Table 6 1 Procedure to Attach Rear Fin Cover to Units 6 5 Table 6 2 Installation Handle Kit SGLN5754 6 6 Table 6 3 Procedure to Attach the Installation Handles to the Unit 6 6 Table 6 4 Procedure to Attach the Unit to the Mounting Bracket 6 9 Table 6 5 Ground Cable Description and Part Number 6 11 Table 6 6 Procedure to Attach t...

Страница 16: ...ocell Expansion Kit for Units 1 to 2 Short MIB A Cubicle T448AL 6 44 Table 6 33 Microcell Expansion Kit for Units 1 to 2 Long MIB A Non Cubicle T448AM 6 45 Table 6 34 Picocell Expansion Kit for Units 1 to 2 Short MIB A Cubicle T448AN 6 45 Table 6 35 Picocell Expansion Kit for Units 1 to 2 Long MIB A Non Cubicle T448AP 6 45 Table 6 36 Microcell Picocell Expansion Kit for Units 2 to 3 Current 2m MIB...

Страница 17: ... and Login to the BTS 7 25 Table 7 13 Update BTS Specific CDF File Device Load Version 7 26 Table 7 14 Download Enable MAWI 7 27 Table 7 15 System Status LED States 7 28 Table 7 16 Selecting Test Equipment Manually in a Serial Connection Tab 7 30 Table 7 17 Selecting Test Equipment Using Auto Detect 7 31 Table 7 18 Test Equipment Calibration 7 32 Table 7 19 R3465 Calibration Procedure 7 33 Table 7...

Страница 18: ...Diskette to the CBSC 8 13 Table 9 1 Login and Access Alarm Window Procedure 9 4 Table 9 2 Shut Down Signaling Functions 9 5 Table 9 3 Restore Signaling Operations 9 9 Table 9 4 Item Number Replacement List 9 13 Table 9 5 Remove the Failed Site I O Junction Box 9 14 Table 9 6 Install the Replacement Site I O Junction Box 9 14 Table 9 7 Item Number Replacement List 9 16 Table 9 8 Remove the Failed S...

Страница 19: ...system and equipment training offered by Motorola although it can be used to supplement or enhance the knowledge gained through such training Text conventions The following special paragraphs are used in this manual to point out information that must be read This information may be set off from the surrounding text but is always preceded by a bold title in capital letters The four categories of th...

Страница 20: ...required by a CMR when new options and procedures become available for general use or when engineering changes occur The cover sheet s that accompany each CMR should be retained for future reference Refer to the Revision History page for a list of all applicable CMRs contained in this manual Receiving updates Technical Education Documentation TED maintains a customer database that reflects the typ...

Страница 21: ...over or title page the page number found at the bottom of each page where the error is located and any comments you may have regarding what you have found We appreciate any comments from the users of our manuals 24 hour support service If you have any questions or concerns regarding the operation of your equipment please contact the Customer Network Resolution Center for immediate assistance The 2...

Страница 22: ...r plugged into an approved three contact electrical outlet or used with a three contact to two contact adapter The three contact to two contact adapter must have the grounding wire green firmly connected to an electrical ground safety ground at the power outlet The power jack and mating plug of the power cable must meet International Electrotechnical Commission IEC safety standards Do not operate ...

Страница 23: ...for service and repair to ensure that safety features are maintained Dangerous procedure warnings Warnings such as the example below precede potentially dangerous procedures throughout this manual Instructions contained in the warnings must be followed You should also employ all other safety precautions that you deem necessary for the operation of the equipment in your operating environment Danger...

Страница 24: ... 2 15 x x Version Information The following table lists the manual version date of version and remarks on the version Version Level Date of Issue Remarks 1 SEP 2000 Draft version for Engineering review Cellular Manual Revision Information The following table lists Cellular Manual Revision CMR number date of CMR and remarks on the CMR Revision Level Date of Issue Remarks CMR No N A No CMRs apply to...

Страница 25: ... 5311571 4369522 4754450 4914696 5067139 5146610 5222141 5274845 5313489 4375622 4764737 4918732 5068625 5152007 5222251 5276685 5319712 4485486 4764849 4941203 5070310 5155448 5224121 5276707 5321705 4491972 4775998 4945570 5073909 5157693 5224122 5276906 5321737 4517561 4775999 4956854 5073971 5159283 5226058 5276907 5323391 4519096 4797947 4970475 5075651 5159593 5228029 5276911 5325394 4549311...

Страница 26: ...Patent Notification continued PRELIMINARY SCt300 BTS Hardware Installation ATP and FRU Procedures DEC 2000 xxiv Notes ...

Страница 27: ... and Materials for Installing the Mounting Bracket on a Rack 1 13 Tools and Materials for Installing the Mounting Bracket on a Concrete Wall 1 14 Tools and Materials for Installing the Mounting Bracket on a Concrete Ceiling 1 15 ATP Tools and Equipment 1 16 Policy 1 16 Test equipment calibration 1 16 Test cable calibration 1 16 Equipment Warm up 1 16 Test Equipment List 1 17 Optional Equipment 1 2...

Страница 28: ...Table of Contents continued PRELIMINARY SCt300 BTS Hardware Installation ATP and FRU Procedures DEC 2000 Notes 1 ...

Страница 29: ... procedures defined in Chapter 6 of this manual Chapter 1 Introduction This is a brief outline of the manual Also provided is a list of additional documents and tools necessary to complete the procedures Chapter 2 Site Preparation This chapter contains the necessary information to verify the condition of the site Chapter 3 Installing Mounting Bracket and Remote GPS This chapter contains the necess...

Страница 30: ...dures provided in this document be sure that S for an internal installation the site is kept clean and free of tracked in dirt S all packing material has been removed from the equipment S all tools not currently in use are picked up as the installation progresses S all trash is removed from the site at the end of each day and after the installation is complete S equipment is covered with a tarpaul...

Страница 31: ... Suppressor for all outside mounting applications S Use fin covers on the Microcell or Picocell for indoor applications S The Primary Surge Suppressor uses solar covers only The battery configurations for the MicroCell and PicoCell units are S Short duration battery The power configurations for the MicroCell and PicoCell units are S AC power only S DC power only S AC power with short duration batt...

Страница 32: ...tion continued PRELIMINARY SCt300 BTS Hardware Installation ATP and FRU Procedures DEC 2000 1 4 Figure 1 1 MicroCell Unit Mounted on a Wall SYSTEM CABLING IS NOT SHOWN FIN AND SOLAR COVERS REMOVED FOR CLARITY 1 ...

Страница 33: ...ion continued DEC 2000 1 5 SCt300 BTS Hardware Installation ATP and FRU Procedures PRELIMINARY Figure 1 2 Primary Surge Suppressor Mounted on a Wall SYSTEM CABLING IS NOT SHOWN SOLAR COVERS REMOVED FOR CLARITY 1 ...

Страница 34: ...tion continued PRELIMINARY SCt300 BTS Hardware Installation ATP and FRU Procedures DEC 2000 1 6 Figure 1 3 MicroCell Unit Mounted on a Rack SYSTEM CABLING IS NOT SHOWN FIN AND SOLAR COVERS REMOVED FOR CLARITY 1 ...

Страница 35: ...continued DEC 2000 1 7 SCt300 BTS Hardware Installation ATP and FRU Procedures PRELIMINARY Figure 1 4 Primary Surge Suppressor Mounted on a Rack SYSTEM CABLING IS NOT SHOWN FIN AND SOLAR COVERS REMOVED FOR CLARITY 1 ...

Страница 36: ...inued PRELIMINARY SCt300 BTS Hardware Installation ATP and FRU Procedures DEC 2000 1 8 Figure 1 5 MicroCell Unit Mounted on a Pole BACK SOLAR COVER SYSTEM CABLING IS NOT SHOWN FRONT SOLAR COVER IS REMOVED FOR CLARITY 1 ...

Страница 37: ... DEC 2000 1 9 SCt300 BTS Hardware Installation ATP and FRU Procedures PRELIMINARY Figure 1 6 Primary Surge Suppressor Mounted on a Pole BACK SOLAR COVER SYSTEM CABLING IS NOT SHOWN FRONT SOLAR COVER IS REMOVED FOR CLARITY 1 ...

Страница 38: ...Ct300 BTS Hardware Installation ATP and FRU Procedures DEC 2000 1 10 Figure 1 7 PicoCell Unit Mounted on a Ceiling ONLY THE PICOCELL UNIT MAY BE MOUNTED ON THE CEILING SYSTEM CABLING IS NOT SHOWN FIN AND SOLAR COVERS REMOVED FOR CLARITY 1 ...

Страница 39: ...anual S Site Document generated by Motorola Systems Engineering which includes site specific documentation channel allocation contact list customer ancillary expendable equipment list site wiring lists contact list Motorola support job box inventory S Demarcation Document Scope of Work agreement S Grounding Guidelines for Cellular Radio Installations Motorola part number 68P81150E62 S CDMA LMF Ope...

Страница 40: ... document and must be evaluated on a site to site basis Also for each procedure a tools and materials list is provided within the procedure Motorola kit T393AA is available for most installation styles and methods Motorola kit T393AA contains S Torque driver wrench 1 4 in hex female drive 0 10 N m S T20 Torx Tamper Bit 1 4 in hex S T30 Torx Tamper Bit 1 4 in hex S Flathead bit S Torque ratchet wre...

Страница 41: ... tape customer supplied T30 TORX tamper bit 1 4 in hex pp Torque driver wrench 1 4 in hex female drive 0 10 N M Ball Peen Metal Working Hammer Heavy Gloves Tape Measure Tools and Materials for Installing the Mounting Bracket on a Rack The following tools and materials are required to properly and safely install the mounting bracket on a rack Table 1 2 Tools and Materials for Rack Mounting Hand Too...

Страница 42: ...ble 1 3 Mounting Bracket Tools and Materials for Concrete Wall Mounting Hand Tools Materials Power Tools T30 Torx tamper bit 1 4 in hex metal shim material Hilti wall drilling rig 15 16 in 23 8 mm socket a ratchet wrench and an 18 in 45 7 cm breaker bar Hilti anchors for each bracket Hilti DCM 18 14 metric bit safety glasses MicroCell or PicoCell Mounting Kit shop vacuum chalk for marking outline ...

Страница 43: ...ete Ceiling Hand Tools Materials Power Tools T30 Torx tamper bit 1 4 in hex metal shim material Hilti wall drilling rig Torque driver wrench 1 4 in hex female drive 0 10 N M Hilti anchors qty of 4 for each bracket Hilti DCM 18 14 metric bit 15 16 in 23 8 mm socket a ratchet wrench and an 18 in 45 7 cm breaker bar PicoCell Mounting Kit shop vacuum safety glasses Ceiling Mounting Kit chalk for marki...

Страница 44: ...characterization Follow the original equipment manufacture OEM recommended maintenance and calibration schedules closely Test cable calibration Equipment test cables are very important in the ATP It is recommended that the cable calibration be run at every BTS with the test cables attached This method compensates for test cable insertion loss within the test equipment itself No other allowance for...

Страница 45: ...66 MHz 32 bit CPU Pentium processor S 4 Gbyte internal hard disk drive S Color display with 1024 x 768 recommended or 800 x 600 pixel resolution S 128 MB RAM S CD ROM drive S 3 1 2 inch floppy drive S Serial port COM 1 S Parallel port LPT 1 S PCMCIA Ethernet interface card for example 3COM Etherlink III with a 10Base T to coax adapter S Windows 98 or higher operating system If 800 x 600 pixel reso...

Страница 46: ...ackard HP 8935 S Hewlett Packard HP8921 w CDMA and PCS interface for 1 7 1 9 GHz and HP 437B or Gigatronics Power Meter S RF power meter average and code domain S RF signal generator capable of CDMA modulation S Spectrum Analyzer S CDMA code domain analyzer As of the writing of this manual the Advantest CDMA communications test set is the ONLY CDMA analyzer approved by Motorola for automated BTS t...

Страница 47: ... used to allow self calibration of the Communication Test Set Male BNC to male cable One male BNC to male cable This cable connects the 2 Second Reference to the external trigger of the Communication Test Set Male BNC to Male SMA cable Two male BNC to male SMA cables These cables are is used to connect the BTS 19 6608 MHz and 2 Second Reference to the Communication Test Set Ohm load One male N 50 ...

Страница 48: ...Spectrum analyzer Spectrum Analyzer HP8594E with CDMA personality card or equivalent Required for manual tests other than standard tests performed by the LMF Span line JT1 verification equipment As required for local application RF test cable if not provided with test equipment Motorola model TKN8231A Used to connect test equipment to the BTS during ATP or general troubleshooting procedures Oscill...

Страница 49: ...Kit SG1476AA 2 A Band BTS without HSO Kit SG1477AA 3 B Band BTS with HSO Kit SG1484AA 4 B Band BTS without HSO Kit SG1485AA 5 Fin Cover Kit T389AA MicroCell 1 A Band BTS with HSO Kit SG1478AA 2 A Band BTS without HSO Kit SG1479AA 3 B Band BTS with HSO Kit SG1486AA 4 B Band BTS without HSO Kit SG1487AA 5 Solar Cover Kit T451AA 6 Fin Cover Kit T389AB Tools and Materials Required to Perform FRU Proce...

Страница 50: ...igure 1 9 and Figure 1 10 show the various components of the MicroCell and PicoCell systems Figure 1 9 General Block Diagram Showing the Port Names MicroCell Unit Shown SITE I O JUNCTION BOX DC POWER BREAKER DC INPUT MIB C MIB B MIB A ANTENNA A AC POWER BREAKER AC INPUT SU RF SU 2 SU 1 ANTENNA B MICROCELL ONLY 1 ...

Страница 51: ... and FRU Procedures PRELIMINARY Figure 1 10 General Block Diagram Showing the Unit Site I O Interface and External Items ANT RX ANT TX RX CUSTOMER INPUTS SPAN RGPS DC POWER PHONE MODEM AC POWER SITE I O INTERFACE MICROCELL ONLY MicroCell Unit Shown MIB TERMINATOR MICROCELL ONLY 1 ...

Страница 52: ...cation continued PRELIMINARY SCt300 BTS Hardware Installation ATP and FRU Procedures DEC 2000 1 24 Figure 1 11 Microcell and Picocell Unit MICROCELL UNIT PICOCELL UNIT Figure 1 12 Site I O Junction Box and Cable 1 ...

Страница 53: ...UnitIdentification continued DEC 2000 1 25 SCt300 BTS Hardware Installation ATP and FRU Procedures PRELIMINARY Figure 1 13 Primary Surge Suppressor Optional Figure 1 14 AC Installation Box Optional 1 ...

Страница 54: ...ion continued PRELIMINARY SCt300 BTS Hardware Installation ATP and FRU Procedures DEC 2000 1 26 Figure 1 15 Mounting Bracket for both Microcell and Primary Surge Suppressor Figure 1 16 Mounting Bracket for Picocell 1 ...

Страница 55: ...UnitIdentification continued DEC 2000 1 27 SCt300 BTS Hardware Installation ATP and FRU Procedures PRELIMINARY Figure 1 17 Adapters for Rack Mounting 1 ...

Страница 56: ...re Installation ATP and FRU Procedures DEC 2000 1 28 Figure 1 18 Adapters for Pole Mounting CHANNEL EXTRUSION CHANNEL CLAMP SEE DETAIL A BUCKLESTRAP UPPER CHANNEL EXTRUSION CHANNEL CLAMP CHANNEL CLAMP LOWER CHANNEL EXTRUSION DETAIL A SEE DETAIL A BUCKLESTRAP 1 ...

Страница 57: ... 2000 1 29 SCt300 BTS Hardware Installation ATP and FRU Procedures PRELIMINARY Figure 1 19 Adapter for Ceiling Mounting Optional Figure 1 20 Installation Handles for Lifting Unit Optional Figure 1 21 Short Duration Battery Optional 1 ...

Страница 58: ...NARY SCt300 BTS Hardware Installation ATP and FRU Procedures DEC 2000 1 30 Figure 1 22 Front and Back Solar Covers for MicroCell FRONT COVER BACK COVER Figure 1 23 Front and Back Solar Covers for Surge Suppressor FRONT COVER BACK COVER 1 ...

Страница 59: ...tion continued DEC 2000 1 31 SCt300 BTS Hardware Installation ATP and FRU Procedures PRELIMINARY Figure 1 24 Front and Back Fin Covers for MicroCell and PicoCell PicoCell shown BACK COVER FRONT COVER 0149 O_IL doc 1 ...

Страница 60: ...g bracket optional 10 Remove installation handles if used 11 Remove Site I O dust cover 12 Attach Site I O junction box to unit 13 Attach all ground cabling to unit s 14 Attach all cables to unit s 15 Install short duration battery if required 16 Attach front solar cover optional 17 Attach front fin cover optional ATP Order The ATP for the MicroCell and PicoCell units is performed in the following...

Страница 61: ...sts 18 Generate an ATP Report 19 Copy LMF CAL file to CBSC 20 Terminate LMF session leave the site Frequency Hopping Pilot Beacon ATP Order The Frequency Hopping Pilot Beacon FHPB ATP for the MicroCell and PicoCell units is performed in the following sequence 1 Create CAL file 2 RF path audit 3 TX Acceptance tests 4 Generate an ATP Report 5 Copy LMF CAL file to CBSC 6 Terminate LMF session leave t...

Страница 62: ...Installation and ATP Order continued PRELIMINARY SCt300 BTS Hardware Installation ATP and FRU Procedures DEC 2000 1 34 Notes 1 ...

Страница 63: ...2 2 Inspection Overview 2 2 Deficiencies 2 2 What to Inspect 2 2 Antenna and Tower Inspections 2 2 Structural Inspections and Verifications 2 3 Environmental Inspections indoor only 2 5 Grounding Inspections 2 5 Prepare Site for the Arrival of the Equipment 2 6 Description 2 6 Equipment Arrival 2 6 Securing Fluorescent Lights 2 6 Procedure to Prepare the Site for the Equipment 2 7 Dimensions and C...

Страница 64: ...Table of Contents continued PRELIMINARY SCt300 BTS Hardware Installation ATP and FRU Procedures DEC 2000 Notes 2 ...

Страница 65: ...pply to both types indoor and outdoor of installations It is stated when a preparation applies to only one type of installation All indoor installations must be in a restricted access location Verifications and Procedures The verifications and procedures provided in this chapter are S External site inspections S Internal site inspections S Preparing site for the arrival of equipment S Site layout ...

Страница 66: ...ller is not responsible for correcting the noted deficiencies Deficiencies may need to be corrected before any installation can start What to Inspect The following external items should be inspected and compared against any related site specific documentation S Towers S Antennas S External ground systems S Clearances for units S Mounting Structures Additionally for all sites the incoming power sho...

Страница 67: ...s stated in the site specific documentation Cabling rack For indoor installations inspect the cable rack for proper installation The cable racks should be at least 7 ft from the floor The cable racks should be electrically tied together with 6 AWG wire except cable racks that are in an isolated ground zone Fire protection For indoor installations verify with the site manager that some type of fixe...

Страница 68: ...the fluid if feasible Contact the following office for information 3M Center Performance Materials Division Building 223 6S 04 St Paul MN 55144 800 833 5045 The short duration battery is a lead acid battery Do not incinerate IMPORTANT The Material Safety Data Sheet MSDS for Lead Acid Batteries states the spent battery should be sent to a secondary lead smelter for recycling Antenna cables and port...

Страница 69: ...ons even though it is designed to operate in extreme temperatures GroundingInspections For external installations For outside installations refer to the site specific documentation For internal installations For indoor installations refer to the Grounding Guideline for Cellular Radio Installations 68P81150E62 for all grounding inspection procedures Verify the following S All ground cables have a b...

Страница 70: ...ompany an area at the site where the equipment can be unloaded and if necessary unpacked The equipment should be carefully delivered to the site along with all equipment dollies and padding required to safely move the equipment from the unloading area to the cell site The following should also be provided outdoor weather protection temporary lighting and power for lighting and power tools Securing...

Страница 71: ...tion of equipment or cables 4 Locate the demarcation blocks for external utilities Verify that they are shown on the Site Engineering documents and determine the required cable routing back to the equipment frames 5 Verify the following S DC power is available and meets the site documentation specifications if applicable S AC power is available and meets the site documentation specifications if ap...

Страница 72: ...ons for the MicroCell and PicoCell Units Item Height Width Depth Weight MicroCell fully installed 730 mm 28 76 in 590 mm 23 25 in 254 mm 10 01 in 38 5 kg 84 7 lbs MicroCell unit only 590 mm 23 22 in 450 mm 17 71 in 150 mm 5 90 in 24 kg 52 8 lbs PicoCell fully installed 525 mm 20 66 in 500 mm 19 68 in 144 mm 5 66 in 30 5 kg 67 1 lbs PicoCell unit only 510 mm 20 08 in 450 mm 17 71 in 110 mm 4 33 in ...

Страница 73: ...nd Maintenance Requirements 200 mm 7 87 in 100 mm 3 93 in 0 0 0 600 mm 23 62 in Functional Requirements without solar cover 1000 mm 39 37 in 0 1000 mm 39 37 in 1000 mm 39 37 in 0 0 Within these boundaries area must remain 75 unobstructed This is the open surface area at any cross section Within these boundaries area must remain 25 unobstructed This is the open surface area at any cross section See...

Страница 74: ...0 Unit Dimensions The unit dimensions are shown below Figure 2 2 Overall Dimensions of MicroCell and PicoCell Units PicoCell Unit MicroCell Unit 730mm 28 76 in 590 mm 23 25 in 450mm 17 71in 590mm 23 22in 150mm 5 90in 450mm 17 71in 510mm 20 08 in 110mm 4 33in 500mm 19 68in 144mm 5 66in 525mm 20 66in 254 mm 10 01 in 2 ...

Страница 75: ...300 BTS Hardware Installation ATP and FRU Procedures PRELIMINARY Figure 2 3 Overall Dimensions of Primary Surge Suppressor 125 mm 4 93 in 465 mm 18 32 in 510 mm 20 08 in 730mm 28 76 in 590 mm 23 25 in 254 mm 10 01 in With Solar Cover Without Solar Cover 2 ...

Страница 76: ...elow Figure 2 4 Installation and Functional Clearances for MicroCell Units with Solar Covers 50 mm air exhaust area 50 mm air intake area 100 mm clearance for installation handles 200 mm clearance for tool access 600 mm from front of unit for FRU installation and removal MICROCELL WITH SOLAR COVERS 0 mm Functional Clearance in Front of Microcell With Solar Cover 2 ...

Страница 77: ...e 2 5 Installation and Functional Clearances for MicroCell Units without Solar Covers 50 mm air exhaust area 100 mm clearance for installation handles 200 mm clearance for tool access 50 mm air intake area 600 mm from front of unit for FRU installation and removal MICROCELL WITHOUT SOLAR COVERS 50 mm Air Intake Functional 2 ...

Страница 78: ...tallation and Functional Clearances for PicoCell Units without Solar Covers 50 mm air exhaust area 100 mm clearance for installation handles 200 mm clearance for tool access 50 mm air intake area 50 mm Air Intake Area Functional 600 mm from front of unit for FRU installation and removal 0196 O_IL doc PICOCELL WITHOUT SOLAR COVERS 2 ...

Страница 79: ...Procedures PRELIMINARY Figure 2 7 Installation and Functional Clearances for Primary Surge Suppressor without Solar Covers 200 mm clearance for tool access 600 mm from front of unit for unit installation and removal PRIMARY SURGE SUPPRESSOR WITHOUT SOLAR COVERS 200 mm clearance for tool access 2 ...

Страница 80: ...U Procedures DEC 2000 2 16 Figure 2 8 Installation and Functional Clearances for Primary Surge Suppressor with Solar Covers 200 mm clearance for tool access 600 mm from front of unit for FRU installation and removal PRIMARY SURGE SUPPRESSOR WITH SOLAR COVERS 200 mm clearance for tool access 2 ...

Страница 81: ...nctional Clearances for PicoCell Unit Mounted to Ceiling For PicoCell horizontal mounting assume unit is in a volume 400H x 600W x 500D as shown below Additional clearances are measured from edge of the volume 500mm 600mm 500mm FUNCTIONALITYCLEARANCES INSTALLATION CLEARANCES CEILING CEILING 600mm 400mm 1000mm 1000mm 1000mm 400mm 600mm 200mm 100mm 2 ...

Страница 82: ...cedures DEC 2000 2 18 Figure 2 10 Concept of Functionality Clearances for MicroCell and PicoCell Units THIS ILLUSTRATION SHOWS THE CONCEPT OF HOW THE AREA ABOVE AND BELOW THE SCt340 BTS SHOULD BE AT LEAST 25 UNOBSTRUCTED THERE IS NO BOX AROUND THE UNIT BOX IS USED FOR ILLUSTRATION PURPOSES ONLY 2 ...

Страница 83: ...cket to a Ceiling 3 9 Objective 3 9 Mounting Bracket Hole Locations 3 9 Tools and Materials for Installing the Mounting Bracket on a Ceiling 3 10 Securing Mounting Bracket to Adapter 3 11 Attaching the Mounting Bracket to a Pole 3 12 Objective 3 12 Required Tools and Materials for Pole Mounting 3 12 Procedure to Attach the Mounting Bracket to a Pole 3 13 Attaching the Mounting Bracket to a Rack 3 ...

Страница 84: ...Table of Contents continued PRELIMINARY SCt300 BTS Hardware Installation ATP and FRU Procedures DEC 2000 Notes 3 ...

Страница 85: ...S Install the mounting bracket on a wall pole rack or ceiling S Attach the unit and covers to the mounting bracket Procedure order The process of installing the mounting bracket and Remote GPS receiver requires that the following procedures be completed in the order shown 1 Unpack the equipment and inspect for damage 2 Install the mounting hardware on a wall rack pole or ceiling 3 Attach the back ...

Страница 86: ...e S Ceiling mounting adapter Optional Kit T391AA S External cables AC input DC input and SU S Lower pin S Site I O junction box and cable assembly S Terminations S AC Installation Box required for outdoor applications Box 2 S Microcell or Picocell unit Box 3 Optional S Primary Surge Suppressor S Solar covers S Mounting bracket S Rack mounting adapters and hardware S Pole mounting adapters and hard...

Страница 87: ...3 3 SCt300 BTS Hardware Installation ATP and FRU Procedures PRELIMINARY Inspect items for S dents S scratches S bent pins in connectors S squareness of bracket S damage to heatsink fins S isolating pads washers on mounting bracket S frayed cabling or chafed connectors 3 ...

Страница 88: ... always consult a licensed Civil Engineer to determine the exact Zone 3 and or Zone 4 compliance of your specific site CAUTION If your site requires the optional Primary Surge Suppressor then you must install two mounting brackets NOTE Mounting Bracket Hole Locations Figure 3 1 shows the holes to use to attach the mounting bracket to a wall Figure 3 1 Holes to Use to Mount the Bracket to the Wall ...

Страница 89: ...ing bolts that are appropriate for the particular walls on which the BTS will be mounted Concrete wall The following tools and materials are required to properly and safely install the the mounting bracket on a concrete wall Table 3 1 Mounting Bracket Tools and Materials for Concrete Wall Mounting Hand Tools Materials Power Tools T30 Torx tamper bit 1 4 in hex metal shim material Hilti wall drilli...

Страница 90: ...em 2 Hold the bracket in position and mark the mounting hole locations 3 Prepare a standard 3 8 electric drill or the Hilti wall drilling rig 4 Install the appropriate bit in the drill using the following information S For concrete walls use the Hilti DCM 18 14 metric bit and Hilti anchors 5 Begin to drill by using short bursts until the bit has a bite into the wall 6 Run the drill at full speed t...

Страница 91: ...chor into each mounting hole Tap each anchor using a rubber mallet until each anchor is completely seated in a hole 2 Position the mounting bracket on the wall over the mounting holes Start but do not tighten all bolts CAUTION Only put shims under the bracket where the isolation pad is present Do not place shims so that they will contact the bare metal of the frame 3 Place a 4 ft 1 22 m level on t...

Страница 92: ...TOP TO BOTTOM BOLT AND PLASTIC SHOULDER WASHER THREADED INTO ANCHOR THROUGH MOUNTING BRACKET ÉÉÉ ÉÉÉ Ä Ä ÉÉ ÉÉ ÉÉ ÉÉ ÉÉ ÉÉ ÉÉÉ ÄÄ ÄÄ É É É É É É É FROM TOP TO BOTTOM LAG SCREW AND PLASTIC SHOULDER WASHER THREADED INTO PILOT HOLE THROUGH MOUNTING PLATE BRACKET FOR CLARITY THE REST OF THE BRACKET IS NOT SHOWN LAG SCREW CONCRETE ANCHOR STUD WALL PLACE SCREW THROUGH HOLES 0156 O_IL doc 3 ...

Страница 93: ...termine the exact Zone 3 and or Zone 4 compliance of your specific site CAUTION The top surface of the ceiling adapter must be mounted horizontally The bubble level indicator in the center of the bracket must have the bubble in the center of the inner black circle after mounting the adapter Failure to do so could cause damage to the unit and would void the warranty CAUTION Mounting Bracket Hole Lo...

Страница 94: ...he the ceiling adapter on a concrete ceiling Table 3 4 Tools and Materials for Concrete Ceiling Hand Tools Materials Power Tools 15 16 in 23 8 mm socket a ratchet wrench and an 18 in 45 7 cm breaker bar metal shim material Hilti wall drilling rig safety glasses Hilti anchors qty of 4 for each bracket Hilti DCM 18 14 metric bit T30 Torx tamper bit 1 4 in hex Ceiling Mounting Kit shop vacuum Torque ...

Страница 95: ...ting Bracket to the Adapter Step Action 1 Verify that isolating pads and bracket mounted shoulder washers are installed on the bracket If not contact the site manager 2 Position the mounting bracket on the ceiling adapter and align the mounting holes See Figure 3 4 3 Use a T30 Torx tamper bit to start but not tighten the M6x19 screws in each mounting hole Begin with the outer holes and work toward...

Страница 96: ...ervice personnel by being placed near high voltage or other hazardous conditions S All cabling must be constrained in or on the pole in accordance to local building codes WARNING For all applications always consult a licensed Civil Engineer to determine the exact Zone 3 and or Zone 4 compliance of your specific site CAUTION Required Tools and Materials for Pole Mounting The following tools and mat...

Страница 97: ...hannel clamp See Figure 3 5 6 Wrap the bucklestrap around the pole and through the fitting on the end of the band Pull the band until it is makes concentric contact with the pole 7 Start but do not tighten the lower channel extrusion to the mounting bracket Use 2 M6x19 tamper resistant screws 8 Before you tighten the lower strap attach the mounting bracket to the top channel extrusion 9 Slide the ...

Страница 98: ... Figure 3 5 Pole Adapter and Straps CHANNEL CLAMP UPPER CHANNEL EXTRUSION PART NUMBER 0709991S02 LOWER CHANNEL EXTRUSION PART NUMBER 0709991S03 CHANNEL CLAMP PART NUMBER 4209992S01 SIDE VIEW OF CHANNEL CLAMP AND BAND CHANNEL CLAMP PART NUMBER 4209992S01 BUCKLESTRAP PART NUMBER 4209993S04 0159 O_IL doc CHANNEL EXTRUSION BUCKLESTRAP 3 ...

Страница 99: ...g the Mounting Bracket to a Pole continued DEC 2000 3 15 SCt300 BTS Hardware Installation ATP and FRU Procedures PRELIMINARY Figure 3 6 Attaching Mounting Bracket to a Pole M6x19 SCREWS PART NUMBER 0387541C03 3 ...

Страница 100: ...tapping customer supplied Chalk or marker to mark location on rack electrical tape customer supplied Procedure to Attach the Mounting Bracket to a Rack To attach the mounting bracket to a rack follow the procedure in Table 6 10 Table 3 9 Procedure to Attach the Mounting Bracket to a Rack Step Action 1 Verify that isolating pads and washers are installed in the bracket If not contact the site manag...

Страница 101: ...ocedures PRELIMINARY Table 3 9 Procedure to Attach the Mounting Bracket to a Rack Step Action 6 Use two machine screws customer supplied to attach the lower rack adapter to the rack 7 Use a T30 Torx tamper bit to torque the screws connecting the mounting bracket to the upper and lower adapters Torque to 5 0 N M 3 ...

Страница 102: ...TP and FRU Procedures DEC 2000 3 18 Figure 3 7 Attaching the Mounting Bracket to a Rack A MACHINE SCREW 12 24 5 8 IN CUSTOMER SUPPLIED RACK ADAPTER PART NUMBER 0709994S01 MOUNTING BRACKET PART NUMBER 0709994S01 OR S02 RACK ADAPTER PART NUMBER 0709994S01 M6 x19 SCREW 4 M6 x 19 SCREW 2 A A A A 3 ...

Страница 103: ...r to the mounting bracket S Torque driver wrench 1 4 in hex female drive 0 10 N M S T30 Torx bit Procedure Attach the back solar cover to the mounting bracket by following the procedure in Table 3 10 and the information in Figure 3 8 Table 3 10 Procedure to attach Back Solar Cover to Mounting Bracket Step Action 1 Place the back solar cover on the mounting bracket so the cooling vents are at the t...

Страница 104: ... Solar Cover to Mounting Bracket continued PRELIMINARY SCt300 BTS Hardware Installation ATP and FRU Procedures DEC 2000 3 20 Figure 3 8 Attaching MicroCell Back Solar Cover to Mounting Bracket M6 SCREWS 0309959S06 3 ...

Страница 105: ...ing on the radome of the RGPS head Place the RGPS head as far away from the BTS transmit antenna as possible to avoid RF interference issues Do not install the RGPS head close to a lightning rod A lightning rod attracts lightning which can damage or destroy the RGPS head Also since a lightning rod is connected to an earth ground it can act as a shield and create a shadow that may block or reduce t...

Страница 106: ...nsert the pipe into the threaded neck on the RGPS head and hand tighten 6 Place the assembly into the mounting brackets and secure with the two clamp brackets U bolts and nuts as shown in Figure 3 9 Figure 3 9 Installing the Remote GPS Head WALL MOUNTING BRACKETS 2 CLAMP BRACKETS 2 U BOLTS CABLE TO SITE I O INTERFACE REFER TO VIEW A CABLE TO SITE I O INTERFACE RGPS HEAD WITH 12 PIN MALE CONNECTOR ...

Страница 107: ...r Grounding Considerations 4 16 Power Requirements and Configurations 4 16 Cables Needed 4 17 AC Input Cable Information 4 17 DC Input Cable Information 4 18 Antenna Cabling for Sites Equipped With Customer Supplied Site I O Interface 4 21 Objective 4 21 Cable Labels 4 21 Equipment Needed 4 21 Antenna Cable Pin and Signal Information 4 21 Procedure to Install Antenna Cabling for One Antenna 4 22 P...

Страница 108: ...ble to the Site I O Interface 4 29 Connecting a Phone Line to the Site I O Interface Modem Support 4 30 RGPS Cabling for Multi BTS Configurations 4 31 Overview 4 31 Background 4 31 Required Equipment 4 31 Cable Diagram 4 32 Procedure 4 32 Cable Connections 4 35 Span Line Daisy Chain Cabling 4 36 Objective 4 36 Background 4 36 Cable Description 4 36 Procedure 4 36 Cable Connections 4 38 4 ...

Страница 109: ...orts cable installation for single carrier omni configurations and multi carrier omni configurations This chapter also supports cable installations for sites equipped with the customer supplied Site I O Interface Chapter 5 supports installations for sites equipped with the optional Primary Surge Suppressor Cabling Installation Order To install the cables Motorola recommends that the following proc...

Страница 110: ...le N type connector D 2 6 Customer Supplied Antenna cable terminated with 2 male N type connectors E 1 3087707C03 MIB A cable current 2m micro part of kit SGEN4068A SGEN4067A and SGEN4061A F 1 3087707C04 MIB B cable current 2m part of kit SGEN4066A SGEN4070A and SGEN4068A G 2 3087707C05 MIB C cable current 2m part of kit SGEN4070A and SGEN4068A H 1 3087707C06 MIB A cable long 2m pico part of kit S...

Страница 111: ...n both ends T 1 Customer Supplied AC Input power cable 10 14 AWG 90_C wire Designed for 120 240 VAC U 1 3087854C04 DC input cable 14 and 22 AWG 5 m is designed for 20 to 30 VDC power input V 1 Customer Supplied Phone Modem cable 22 24 AWG solid copper twisted pair W 1 3 Customer Supplied Span Line Daisy Chain cable X 1 11 3086039H18 RGPS Synchronization cable part of kit SGKN4351A 3086039H19 RGPS ...

Страница 112: ...g SU Cable Table 4 3 Microcell Expansion Kit for Units 1 to 2 Long MIB A Non Cubicle T448AM Cable Qty Motorola Part Number Description n a 2 5882106P01 50 Ohm Antenna Terminator A 1 3087701C02 Ground cable 8 AWG insulated copper wire Requires one ring lug connector E 1 3087707C03 MIB A cable current 2m micro Q 1 3088120C01 Long SU Cable Table 4 4 Picocell Expansion Kit for Units 1 to 2 Short MIB A...

Страница 113: ... 2 to 3 Long 5m MIB B T448AS Cable Qty Motorola Part Number Description A 1 3087701C02 Ground cable 8 AWG insulated copper wire Requires one ring lug connector I 1 3087707C07 MIB B cable long 5m Q 2 3088120C01 Long SU RF Cable R 2 3088120C02 Short SU RF Cable n a 2 5688123C01 SU Splitter n a 2 8009573X06 Lightning arrestor Table 4 8 Microcell Picocell Expansion Kit for Units 3 to 4 Current 2m MIBs...

Страница 114: ...l Expansion Kit for Units 3 to 4 Current 2M MIBs B and C T448AV Cable Qty Motorola Part Number Description n a 2 5882106P01 50 Ohm Antenna Terminator A 1 3087701C02 Ground cable 8 AWG insulated copper wire Requires one ring lug connector E 1 3087707C03 MIB A cable current 2m micro F 1 3087707C04 MIB B cable long 2m G 2 3087707C05 MIB C cable long 2m Q 1 3088120C01 Long SU RF Cable Table 4 11 Picoc...

Страница 115: ...GPS cabling between multiple BTS locations Table 4 12 RGPS Synchronization Cable Kit SGKN4351A Cable Qty Motorola Part Number Description X 1 3086039H18 RGPS Sync Cable 2000 ft n a 2 5864461A03 Fitting liquid tight n a 2 0264599A02 Nut nylon locking Table 4 13 RGPS Synchronization Cable Kit SGKN4352A Cable Qty Motorola Part Number Description X 1 3086039H19 RGPS Sync Cable 3280 ft n a 2 5864461A03...

Страница 116: ... Microcell MICROCELL 1 CUSTOMER INPUTS SPAN RGPS SITE I O INTERFACE PHONE MODEM LA LA DSU LA AC POWER LA ANT B TX RX LA DC POWER GROUND KEY B 1 ANTENNA LABEL NUMBER OF CABLES NAME Y 1 GROUND C 1 ANTENNA S 1 AC POWER U 1 DC POWER LEGEND LA Lightning Arrestor Z 1 SITE I O CABLE SEE NOTE 1 P 1 SU M 1 RGPS N 1 SPAN O 1 CUSTOMER INPUT V 1 PHONE LA C 1 ANTENNA ANT A RX NOTES 1 If BTS is not equipped wit...

Страница 117: ...D Y 1 GROUND D 1 ANTENNA D 1 ANTENNA U 1 DC POWER U 1 DC POWER LEGEND LA Lightning Arrestor NOTES 1 Site I O junction box and associated cable are present on Microcell 1 only 2 If BTS is not equipped with the primary surge suppressor then you will require the Site I O Cable Extender Cable p n 3088116C01 cable Z 3 The AC Installation Box is required for outdoor applications E 1 MIB OR K 1 MIB Q 1 S...

Страница 118: ... DC POWER U 1 DC POWER U 1 DC POWER Q 1 SU LEGEND LA Lightning Arrestor 2X SU Splitter Combiner Q 1 SU F 1 MIB OR I 1 MIB E 1 MIB OR K 1 MIB OR R 1 SU Q 1 SU LA D 1 ANTENNA ANT 3 RX R 1 SU M 1 RGPS N 1 SPAN O 1 CUSTOMER INPUTS V 1 PHONE Z 1 SITE I O CABLE SEE NOTES 1 AND 2 B 1 GROUND NOTES 1 Site I O junction box and associated cable are present on Microcell 1 only 2 If BTS is not equipped with th...

Страница 119: ...ER U 1 DC POWER U 1 DC POWER U 1 DC POWER Q 1 SU LEGEND LA Lightning Arrestor 2X SU Splitter Combiner Q 1 SU Q 1 SU G 1 MIB OR J 1 MIB R 1 SU R 1 SU Q 1 SU M 1 RGPS W 1 SPAN O 1 CUSTOMER INPUTS V 1 PHONE Z 1 SITE I O CABLE SEE NOTE B 1 GROUND NOTES 1 Site I O junction box and associated cable are present on Microcell 1 only 2 If BTS is not equipped with the primary surge suppressor then you will r...

Страница 120: ...A TX RX LA DC POWER GROUND KEY B 1 ANTENNA LABEL NUMBER OF CABLES NAME Y 1 GROUND D 1 ANTENNA U 1 DC POWER LEGEND LA Lightning Arrestor P 1 SU M 1 RGPS N 1 SPAN O 1 CUSTOMER INPUT V 1 PHONE NOTES 1 If BTS is not equipped with the primary surge suppressor then you will require the Site I O Cable Extender p n 3088116C01 cable Z 2 The AC Installation Box is required for outdoor applications Z 1 SITE ...

Страница 121: ...ROUND D 1 ANTENNA D 1 ANTENNA U 1 DC POWER U 1 DC POWER LEGEND LA Lightning Arrestor 2X SU Splitter Combiner Q 1 SU M 1 RGPS N 1 SPAN O 1 CUSTOMER INPUTS V 1 PHONE Z 1 SITE I O CABLE SEE NOTE B 1 GROUND NOTES 1 Site I O junction box and associated cable are present on Microcell 1 only 2 If BTS is not equipped with the primary surge suppressor then you will require the Site I O Cable Extender Cable...

Страница 122: ... 1 ANTENNA U 1 DC POWER U 1 DC POWER U 1 DC POWER Q 1 SU LEGEND LA Lightning Arrestor 2X SU Splitter Combiner Q 1 SU F 1 MIB OR I 1 MIB R 1 SU R 1 SU Q 1 SU Z 1 SITE I O CABLE SEE NOTE B 1 GROUND M 1 RGPS N 1 SPAN O 1 CUSTOMER INPUTS V 1 PHONE NOTES 1 Site I O junction box and associated cable are present on Microcell 1 only 2 If BTS is not equipped with the primary surge suppressor then you will ...

Страница 123: ...1 DC POWER U 1 DC POWER U 1 DC POWER U 1 DC POWER Q 1 SU LEGEND LA Lightning Arrestor 2X SU Splitter Combiner Q 1 SU Q 1 SU F 1 MIB OR I 1 MIB R 1 SU Q 1 SU R 1 SU M 1 RGPS W 1 SPAN O 1 CUSTOMER INPUTS V 1 PHONE Z 1 SITE I O CABLE SEE NOTE B 1 GROUND NOTES 1 Site I O junction box and associated cable are present on Microcell 1 only 2 If BTS is not equipped with the primary surge suppressor then yo...

Страница 124: ...ocedure covers only the grounding information for the cables that attach to one or more MicroCell or PicoCell units Grounding considerations beyond the ground cables that attach to the MicroCell are summarized in Appendix A Refer to Appendix A and the site documentation for other grounding considerations Power Requirements and Configurations The power requirements for the unit are 120 240 VAC or 2...

Страница 125: ...C02 AC input cable 14 AWG 5 m is designed for 88 260 VAC power input U 1 4 3087854C04 DC input cable 14 and 22 AWG 5 m is designed for 20 to 40 VDC power input Y 1 4 Customer Supplied Ground cable 6 AWG insulated copper wire Requires one ring lug connectors AC Input Cable Information The pinout information for the AC input cable s Cable S is given in Figure 4 9 and Table 4 15 Figure 4 9 AC Input C...

Страница 126: ... Comments A Yellow Switch A No connection B Red Positive Connect to positive terminal of supply C Blue Switch B Connect to negative terminal of supply D Black Negative Connect to negative terminal of supply Procedure The system configuration determines which power cables are installed The ground cable is always installed Based on the system configuration perform the appropriate procedures from the...

Страница 127: ...uting the cable 4 Route cable S from the AC power supply to the unit location Table 4 19 Procedure to Install AC Installation Box Optional Required for Outdoor Installations Step Action 1 Route the AC Power Cable cable T through 1 in conduit from the customer defined AC power source to the AC Installation box Refer to Figure 4 11 and Table 4 20 2 Attach cable T to the connector on the AC Installat...

Страница 128: ...TOR ON INSIDE OF DOOR NOTE Shown with door removed for clarity 1 IN AC CONDUIT TO MICROCELL PICOCELL LOCATION GROUND NEUTRAL LINE CUSTOMER AC INPUT Table 4 21 Procedure to Install DC Input Cable s Step Action 1 Connect the loose wires of cable U DC input cable to the customer defined DC power source Refer to NO TAG for wiring information 2 Verify all connections of cable U with an multimeter prior...

Страница 129: ... the quantities and descriptions of the cables Table 4 22 Cables Needed for Antenna Connections Cable Qty Part Number Description C 1 to 8 Customer Supplied Antenna cable 50 Ohm coaxial terminated with at least one male N type connector Antenna Cable Pin and Signal Information The antenna cabling uses a 50 Ohm coaxial cable The inner conductor provides signaling and the outer conductor provides sh...

Страница 130: ...ntenna Refer to Figure 4 12 and Table 4 23 Procedure to Install Antenna Cabling for Multi Unit Configurations If your site has more than one Microcell or Picocell unit refer to Figure 4 13 or Figure 4 14 for site cabling information Route the antenna cables between the units and the customer supplied lightning arrestors If lighting arrestors are not required route the cabling directly to the anten...

Страница 131: ...ocedures PRELIMINARY Figure 4 14 Antenna Cabling for Maximum of Four Microcells or Picocells MICROCELL PICOCELL 4 MICROCELL PICOCELL 1 MICROCELL PICOCELL 3 MICROCELL PICOCELL 2 ANT 4 TX RX LA ANT 3 TX RX LA ANT 2 TX RX LA ANT 1 TX RX LA KEY B 1 ANTENNA LABEL NUMBER OF CABLES NAME C 1 ANTENNA C 1 ANTENNA C 1 ANTENNA C 1 ANTENNA LA LIGHTNING ARRESTOR 4 ...

Страница 132: ...mber Description M 1 3086039H11 RGPS cable 125 ft 3086039H12 RGPS cable 250 ft 3086039H13 RGPS cable 500 ft 3086039H14 RGPS cable 1000 ft 3086039H15 RGPS cable 2000 ft N 1 Customer Supplied Span Cable 22 24 AWG solid copper twisted pair O 1 Customer Supplied Customer Input Cable 22 24 AWG solid copper twisted pair V 1 Customer Supplied Phone Modem Cable 22 24 AWG solid copper twisted pair Z 1 3088...

Страница 133: ... location s to the Site I O Extender Cable cable Z Route cable Z to the Site I O interface Connect the appropriate connectors within the Site I O interface Refer to Figure 4 15 and Table 4 25 If lightning arrestors are required they must be customer supplied Lightning arrestors are not necessary for sites equipped with optional Primary Surge Suppressor Figure 4 15 Site I O Cabling Details MicroCel...

Страница 134: ...mer Input 3 Signal Green Customer Input 3 Ground Blue Customer Input 4 Signal Customer Input Purple Customer Input 4 Ground Customer Input Grey Customer Input 5 Signal White Customer Input 5 Ground Black Brown Customer Input 6 Signal Black Red Customer Input 6 Ground Black Orange Customer Input 7 Signal Black Yellow Customer Input 7 Ground Black Green Customer Input 8 Signal Black Blue Customer In...

Страница 135: ...low 1 PPS from Head Red Green 1 PPS to Head Sync Forward Red Blue 1 PPS to Head Sync Forward Red Purple RGPS 28V Red Grey RGPS Ground Red White RGPS 28V Orange Black RGPS Ground Orange Brown RGPS 28V Orange Red RGPS Ground Orange Yellow NO CONNECTION Orange Green NO CONNECTION Orange Blue RX TIP Primary Network Orange Purple RX RING Primary Network Orange Grey TX TIP Primary Network Span Network O...

Страница 136: ...ant Yellow Grey TX RING Primary Redundant Span Redundant Yellow White RX TIP Secondary Redundant Green Black RX RING Secondary Redundant Green Brown TX TIP Secondary Redundant Green Red TX RING Secondary Redundant Green Orange MODEM TIP Green Yellow MODEM TIP Phone Modem Green Blue No connection Phone Modem Green Purple No connection Green Grey MODEM RING Green White MODEM RING ConnectingCustomer ...

Страница 137: ... Data to Head Red Brown Receive Port White 1 pps from Head Red Orange 1 PPS Timing Brown Black 1 pps from Head Red Yellow 1 PPS Timing Brown RGPS 28 V Red Purple Power 1 Blue Red White Orange Brown Power 2 Yellow Orange Yellow RGPS Ground Red Grey DC Ground 1 Blue Black Orange Black Orange Red DC Ground 2 Yellow Black Orange Green NOTE The RGPS must also be ground referenced to the BTS digital gro...

Страница 138: ...ued PRELIMINARY SCt300 BTS Hardware Installation ATP and FRU Procedures DEC 2000 4 30 Connecting a Phone Line to the Site I O Interface Modem Support The unit provides a two wire analog phone line interface for modem support The unit Tip and Ring signals are connected to the external phone line Tip and Ring 4 ...

Страница 139: ...es The RGPS Synchronization Cable is contained in the Motorola kits listed in Table 4 27 Table 4 27 Cable Descriptions and Part Numbers Cable Qty Part Number Description X 1 11 3086039H18 RGPS Synchronization cable part of kit SGKN4351A 3086039H19 RGPS Synchronization cable part of kit SGKN4352A Motorola kits Table 4 28 and Table 4 29 show the contents of Motorola kits SGKN4351A and SGKN4352A Thes...

Страница 140: ... 4 32 Cable Diagram Figure 4 16 and Figure 4 17 both show the cabling for multi unit configurations for both RGPS sychronous and HSO non synchronous Procedure Connect the cables Cable O between the RGPS head if used and the site I O junction box of each BTS Refer to the cable run list in Table 4 30 Figure 4 16 and Figure 4 17 4 ...

Страница 141: ...LE RGPS DAISY CHAIN CABLE NOTE 1 EACH BTS MAY CONTAIN UP TO FOUR SC340 UNITS NOTE 2 A MAXIMUM OF 12 BTS MAY BE INTERCONNECTED WITH A MAXIMUM DASIY CHAIN CABLE LENGTH OF 600M BETWEEN EACH BTS A MAXIMUM OF SEVEN BTS MAY BE INTERCONNECTED WITH A MAXIMUM DAISY CHAIN CABLE LENGTH OF 1KM BETWEEN EACH BTS MAXIMUM DISTANCE IS 1 KM SEE NOTE 2 BTS 1 SEE NOTE 1 BTS 3 SEE NOTE 1 BTS 4 SEE NOTE 1 UNIT 4 UNIT 3...

Страница 142: ...E RGPS DAISY CHAIN CABLE MAXIMUM DISTANCE IS 600M SEE NOTE 2 BTS 1 SEE NOTE 1 BTS 2 SEE NOTE 1 BTS 3 SEE NOTE 1 BTS 4 SEE NOTE 1 UNIT 4 UNIT 3 UNIT 2 UNIT 1 UNIT 3 UNIT 2 UNIT 1 UNIT 2 UNIT 1 UNIT 1 X X X MAXIMUM DISTANCE IS 600M SEE NOTE 2 MAXIMUM DISTANCE IS 600M SEE NOTE 2 DOWNSTREAM DOWNSTREAM DOWNSTREAM UPSTREAM UPSTREAM UPSTREAM NOTE 1 EACH BTS MAY CONTAIN UP TO FOUR SC340 UNITS NOTE 2 A MAX...

Страница 143: ...a to Tail Green Black Brown Grey Data from Head Black Grey Data to Tail Green Brown White Data from Head Black White Data from Tail White Black Red Black Data to Head Brown Black Data from Tail White Red Brown Data to Head Brown Red 1 PPS to Tail Brown Black Red Orange 1 PPS from Head Brown Orange 1 PPS to Tail Brown Red Yellow 1 PPS from Head Brown Yellow 1 PPS from Tail Red Black Red Green 1 PPS...

Страница 144: ...T1 E1 span This will reduce the number of spans necessary to support a JCDMA system and minimize unused channels Each BTS may contain up to four units A maximum of 12 BTSs may be combined in a single daisy chain Cable Description The following cables are necessary to do this procedure Table 4 31 Cable Descriptions and Part Numbers Cable Qty Part Number Description N 1 3 Customer Supplied Span Line...

Страница 145: ...E CUSTOMER INPUTS SPAN PHONE MODEM SITE I O INTERFACE SITE I O CABLE CUSTOMER INPUTS SPAN PHONE MODEM SITE I O INTERFACE SITE I O CABLE CUSTOMER INPUTS SPAN PHONE MODEM SITE I O INTERFACE SITE I O CABLE BTS 1 SEE NOTE 1 SPAN LINE DAISY CHAIN CABLE SPAN LINE DAISY CHAIN CABLE SPAN LINE DAISY CHAIN CABLE NOTE 1 EACH BTS SITE MAY CONTAIN UP TO FOUR SC340 UNITS THERE MAY BE A TOTAL OF 12 BTSs IN A DAI...

Страница 146: ... I O Span Line RGPS and Modem Cabling procedure The pin number and wire color are based on the Site I O cable The pin number corresponds to pins on the Site I O junction box connectors NOTE Table 4 32 Cable Run List for Span Line Daisy Chain Cabling BTS 1 Secondary Backhaul BTS 2 Primary Backhaul Color Description Color Description Yellow Black RX TIP Orange Grey TX TIP Yellow Brown RX RING Orange...

Страница 147: ...ry Surge Suppressor 5 12 Objective 5 12 Other Grounding Considerations 5 12 Power Considerations and Configurations 5 12 Cables Needed 5 13 AC Input Cable Information 5 13 DC Input Cable Information 5 14 Antenna Cabling for Sites Equipped With Optional Primary Surge Suppressor 5 18 Objective 5 18 Cable Labels 5 18 Equipment Needed 5 18 Antenna Cable Pin and Signal Information 5 18 Procedure to Ins...

Страница 148: ...urge Suppressor 5 31 Connecting a Phone Line to the Primary Surge Suppressor Modem Support 5 31 RGPS Cabling for Multi BTS Configurations Equipped with Optional Primary Surge Suppressor 5 32 Overview 5 32 Background 5 32 Required Equipment 5 32 Cable Diagram 5 33 Procedure 5 33 Cable Connections 5 36 Span Line Daisy Chain Cabling for Sites Equipped with Optional Primary Surge Suppressor 5 37 Objec...

Страница 149: ...tical for a positive evaluation of the work NOTE ConfigurationsSupported This chapter supports cable installation for single carrier omni configurations and multi carrier omni configurations This chapter supports cable installations for sites equipped with the optional Primary Surge Suppressor Cabling Installation Order To install the cables Motorola recommends that the following procedures be com...

Страница 150: ...essor Chapter 6 shows the scope of work for unit cabling Figure 5 1 Site Cabling for One Microcell with Primary Surge Suppressor MICROCELL 1 CUSTOMER INPUTS SPAN RGPS PHONE MODEM ANT A RX DC POWER KEY B 1 ANTENNA LABEL NUMBER OF CABLES NAME A 1 GROUND U 1 DC POWER SITE I O CABLE P 1 SU M 1 RGPS N 1 SPAN O 1 CUSTOMER INPUTS V 1 PHONE AC POWER T 1 AC POWER C 1 ANTENNA PRIMARY SURGE SUPPRESSOR D 1 AN...

Страница 151: ... POWER KEY B 1 ANTENNA LABEL NUMBER OF CABLES NAME A 1 GROUND U 1 DC POWER E 1 MIB OR K 1 MIB SITE I O CABLE Q 1 SU P 1 SU DC POWER U 1 DC POWER A 1 GROUND PRIMARY SURGE SUPPRESSOR D 1 ANTENNA 2 S 1 AC POWER D 1 ANTENNA 1 S 1 AC POWER B 1 GROUND CUSTOMER INPUTS SPAN RGPS PHONE MODEM M 1 RGPS N 1 SPAN O 1 CUSTOMER INPUTS V 1 PHONE SITE I O INTERFACE ANT A RX AC POWER T 1 AC POWER C 1 ANTENNA MASTER...

Страница 152: ... DC POWER LEGEND 2X SU Splitter Combiner Q 1 SU H 1 SU F 1 MIB OR I 1 MIB SITE I O CABLE R 1 SU R 1 SU Q 1 SU DC POWER U 1 DC POWER DC POWER U 1 DC POWER A 1 GROUND PRIMARY SURGE SUPPRESSOR D 1 ANTENNA 2 S 1 AC POWER D 1 ANTENNA 1 S 1 AC POWER A 1 GROUND D 1 ANTENNA 4 S 1 AC POWER 2X D 1 ANTENNA 3 B 1 GROUND E 1 MIB OR K 1 MIB ANT A RX AC POWER T 1 AC POWER C 1 ANTENNA MASTER GROUND Y 1 MASTER GRO...

Страница 153: ...r Combiner Q 1 SU Q 1 SU G 1 MIB OR J 1 MIB SITE I O CABLE R 1 SU R 1 SU Q 1 SU DC POWER U 1 DC POWER DC POWER U 1 DC POWER DC POWER U 1 DC POWER A 1 GROUND A 1 GROUND PRIMARY SURGE SUPPRESSOR D 1 ANTENNA 2 S 1 AC POWER D 1 ANTENNA 1 S 1 AC POWER A 1 GROUND D 1 ANTENNA 3 S 1 AC POWER D 1 ANTENNA 4 S 1 AC POWER B 1 GROUND E 1 MIB OR K 1 MIB E 1 MIB OR K 1 MIB F 1 MIB OR I 1 MIB CUSTOMER INPUTS SPAN...

Страница 154: ...imary Surge Suppressor PICOCELL 1 DC POWER KEY B 1 ANTENNA LABEL NUMBER OF CABLES NAME A 1 GROUND U 1 DC POWER SITE I O CABLE P 1 SU PRIMARY SURGE SUPPRESSOR D 1 ANTENNA 1 S 1 AC POWER B 1 GROUND CUSTOMER INPUTS SPAN RGPS PHONE MODEM M 1 RGPS N 1 SPAN O 1 CUSTOMER INPUTS V 1 PHONE SITE I O INTERFACE ANT A RX AC POWER T 1 AC POWER C 1 ANTENNA MASTER GROUND Y 1 MASTER GROUND ANT B TX RX C 1 ANTENNA ...

Страница 155: ...POWER KEY B 1 ANTENNA LABEL NUMBER OF CABLES NAME A 1 GROUND U 1 DC POWER H 1 MIB OR L 1 MIB SITE I O CABLE Q 1 SU P 1 SU DC POWER U 1 DC POWER A 1 GROUND PRIMARY SURGE SUPPRESSOR D 1 ANTENNA 2 S 1 AC POWER D 1 ANTENNA 1 S 1 AC POWER B 1 GROUND CUSTOMER INPUTS SPAN RGPS PHONE MODEM M 1 RGPS N 1 SPAN O 1 CUSTOMER INPUTS V 1 PHONE SITE I O INTERFACE ANT A RX AC POWER T 1 AC POWER C 1 ANTENNA MASTER ...

Страница 156: ...D U 1 DC POWER LEGEND 2X SU Splitter Combiner Q 1 SU Q 1 SU F 1 MIB OR I 1 MIB SITE I O CABLE R 1 SU R 1 SU Q 1 SU DC POWER U 1 DC POWER DC POWER U 1 DC POWER A 1 GROUND PRIMARY SURGE SUPPRESSOR D 1 ANTENNA 2 S 1 AC POWER D 1 ANTENNA 1 S 1 AC POWER A 1 GROUND D 1 ANTENNA 3 S 1 AC POWER 2X B 1 GROUND H 1 MIB OR L 1 MIB CUSTOMER INPUTS SPAN RGPS PHONE MODEM M 1 RGPS N 1 SPAN O 1 CUSTOMER INPUTS V 1 ...

Страница 157: ...ombiner Q 1 SU H 1 SU G 1 MIB OR J 1 MIB SITE I O CABLE H 1 SU H 1 SU H 1 SU DC POWER S 1 DC POWER DC POWER U 1 DC POWER DC POWER U 1 DC POWER A 1 GROUND A 1 GROUND PRIMARY SURGE SUPPRESSOR D 1 ANTENNA 2 S 1 AC POWER D 1 ANTENNA 1 S 1 AC POWER A 1 GROUND D 1 ANTENNA 3 S 1 AC POWER D 1 ANTENNA 4 S 1 AC POWER B 1 GROUND H 1 MIB OR L 1 MIB H 1 MIB OR L 1 MIB F 1 MIB OR I 1 MIB CUSTOMER INPUTS SPAN RG...

Страница 158: ...uired to attach the unit to the mounting bracket S Torque driver wrench 1 4 in hex female drive 0 10 N M S T30 Torx tamper bit S Three M6X19 screws Motorola Part Number 0387541C03 Procedure to Attach the Surge Suppressor to the Mounting Bracket Use the procedure in Table 5 1 to attach the surge suppressor to the mounting bracket Refer to Figure 5 9 Table 5 1 Procedure to Attach the Surge Suppresso...

Страница 159: ...2000 5 11 SCt300 BTS Hardware Installation ATP and FRU Procedures PRELIMINARY Figure 5 9 Attaching the Surge Suppressor to the Mounting Bracket HOOKS MOUNTING BRACKET SLIDE CUSTOMER SUPPLIED PADLOCK THROUGH HOLES IN BRACKET OPTIONAL MOUNTING BRACKET M6 SCREWS 3 5 ...

Страница 160: ...that attach to one or more Microcell or Picocell units Grounding considerations beyond the ground cables that attach to the Microcell or Picocell are summarized in Appendix A Refer to Appendix A and the site documentation for other grounding considerations Power Considerations and Configurations The Primary Surge Suppressor is designed for 120 240 VAC 3 wire plus ground single phase The power and ...

Страница 161: ...AC input cable 14 AWG 5 m is designed for 88 260 VAC power input Cable has Deutsch connector on both ends T 1 Customer Supplied AC Input power cable 10 14 AWG 90_C wire Designed for 120 240 VAC U 1 4 3087854C04 DC input cable 14 and 22 AWG 5 m is designed for 20 to 30 VDC power input Y 1 Customer Supplied Master Ground Cable 6 AWG insulated copper wire AC Input Cable Information The information fo...

Страница 162: ...o connection B Red Positive Connect to positive terminal of supply C Blue Switch B Connect to negative terminal of supply D Black Negative Connect to negative terminal of supply Procedure The system configuration determines which power cables are installed The ground cable is always installed Based on the system configuration perform the appropriate procedures from the following tables Table 5 5 P...

Страница 163: ...Suppressor Table 5 7 Procedure to Install AC Input Cable s on a BTS Equipped with Optional Primary Surge Suppressor Step Action 1 Connect the customer supplied AC input cable cable T to the customer defined AC power source Refer to Table 5 3 for wiring information 2 Verify all connections of cable T with an ohmmeter prior to routing the cable 3 Route cable T via 1 in conduit from the customer defi...

Страница 164: ...pressor continued PRELIMINARY SCt300 BTS Hardware Installation ATP and FRU Procedures DEC 2000 5 16 Figure 5 12 Primary Surge Suppressor AC Input Power Connection Locations GROUND NEUTRAL INPUT LINE 1 INPUT LINE 2 1 IN CONDUIT CUSTOMER AC POWER COURCE AC LOAD CENTER ALARM CONNECTION 5 ...

Страница 165: ...rocedures PRELIMINARY Table 5 8 Procedure to Install DC Input Cable s Step Action 1 Connect the loose wires of the DC Input Cable cable U to the customer defined DC power source Refer to Table 5 4 for wiring information 2 Verify all connections of cable U with an ohmmeter prior to routing the cable 3 Route cable U from the DC power supply to the unit location 5 ...

Страница 166: ...ns of the cables Table 5 9 Cables Needed for Antenna Connections Cable Qty Part Number Description C 1 to 8 Customer Supplied Antenna cable 50 Ohm coaxial terminated with at least one male N type connector D 2 6 Customer Supplied Antenna cable terminated with 2 N type connectors Antenna Cable Pin and Signal Information The antenna cabling uses a 50 Ohm coaxial cable The inner conductor provides si...

Страница 167: ...s when you expand from one to two units two to three units and from three to four units IMPORTANT Table 5 11 Procedure to Install Antenna Cabling for Sites Equipped with Primary Surge Suppressor Step Action 1 Route cable D antenna cable between the unit s and the Primary Surge Suppressor 2 Route cable C antenna cable from the Primary Surge Suppressor directly to the antenna s 3 Torque connectors t...

Страница 168: ...UMBER OF CABLES NAME D 1 ANTENNA PRIMARY SURGE SUPPRESSOR MICROCELL 2 D 1 ANTENNA ANTENNA 1 TX RX ANTENNA 2 TX RX C 1 ANTENNA C 1 ANTENNA Figure 5 16 Antenna Cabling for Three Microcells with Primary Surge Suppressor MICROCELL 1 KEY B 1 ANTENNA LABEL NUMBER OF CABLES NAME D 1 ANTENNA PRIMARY SURGE SUPPRESSOR MICROCELL 2 D 1 ANTENNA MICROCELL 3 D 1 ANTENNA D 1 ANTENNA ANTENNA 3 RX ANTENNA 4 TX RX A...

Страница 169: ...KEY B 1 ANTENNA LABEL NUMBER OF CABLES NAME D 1 ANTENNA PRIMARY SURGE SUPPRESSOR MICROCELL 2 D 1 ANTENNA MICROCELL 3 D 1 ANTENNA D 1 ANTENNA MICROCELL 4 ANTENNA 3 TX RX ANTENNA 4 TX RX ANTENNA 2 TX RX ANTENNA 1 TX RX C 1 ANTENNA C 1 ANTENNA C 1 ANTENNA C 1 ANTENNA Figure 5 18 Antenna Cabling for one Picocell with Primary Surge Suppressor PICOCELL 1 KEY B 1 ANTENNA LABEL NUMBER OF CABLES NAME D 1 A...

Страница 170: ... B 1 ANTENNA LABEL NUMBER OF CABLES NAME D 1 ANTENNA PRIMARY SURGE SUPPRESSOR PICOCELL 2 D 1 ANTENNA ANTENNA 1 TX RX ANTENNA 2 TX RX C 1 ANTENNA C 1 ANTENNA Figure 5 20 Antenna Cabling for Three Picocells with Primary Surge Suppressor PICOCELL 1 KEY B 1 ANTENNA LABEL NUMBER OF CABLES NAME D 1 ANTENNA PRIMARY SURGE SUPPRESSOR PICOCELL 2 D 1 ANTENNA PICOCELL 3 D 1 ANTENNA ANTENNA 3 TX RX ANTENNA 2 T...

Страница 171: ...IMINARY Figure 5 21 Antenna Cabling for Four Picocells with Primary Surge Suppressor PICOCELL 1 KEY B 1 ANTENNA LABEL NUMBER OF CABLES NAME D 1 ANTENNA PRIMARY SURGE SUPPRESSOR PICOCELL 2 D 1 ANTENNA PICOCELL 3 D 1 ANTENNA PICOCELL 4 D 1 ANTENNA ANTENNA 3 TX RX ANTENNA 4 TX RX ANTENNA 2 TX RX ANTENNA 1 TX RX C 1 ANTENNA C 1 ANTENNA C 1 ANTENNA C 1 ANTENNA 5 ...

Страница 172: ...D 2 6 Customer Supplied Antenna cable terminated with 2 N type connectors M 1 3086039H11 RGPS cable 125 ft 3086039H12 RGPS cable 250 ft 3086039H13 RGPS cable 500 ft 3086039H14 RGPS cable 1000 ft 3086039H15 RGPS cable 2000 ft N 1 Customer Supplied Span Cable 22 24 AWG solid copper twisted pair O 1 Customer Supplied Customer Input Cable 22 24 AWG solid copper twisted pair T 1 Customer Supplied AC In...

Страница 173: ... Site I O Junction Box and Optional Primary Surge Suppressor Step Action 1 Route the Site I O cable s from the unit location to the Primary Surge Suppressor 2 Connect the Site I O cable from unit 1 to the connector labeled SITE I O 1 on the right side of the Surge Suppressor 3 Connect the appropriate conductors or wires to the Primary Surge Suppressor Punchdown block Figure 5 22 Site I O Cabling D...

Страница 174: ...r Sites Equipped With Primary Surge Suppressor continued PRELIMINARY SCt300 BTS Hardware Installation ATP and FRU Procedures DEC 2000 5 26 Figure 5 23 Punchdown Block Location PUNCHDOWN BLOCK PRIMARY SURGE SUPPRESSOR Figure 5 24 Punchdown Block 5 ...

Страница 175: ...continued DEC 2000 5 27 SCt300 BTS Hardware Installation ATP and FRU Procedures PRELIMINARY Pin and Signal Information for Surge Suppressor Punchdown Block Cabling Table 5 14 gives the pin and signal information for connecting the loose wires to the customer locations on the Punchdown Block 5 ...

Страница 176: ...OSP 3R Customer Input 3 Ground OSP 4T Customer Input 4 Signal Customer Input OSP 4R Customer Input 4 Ground Customer Input OSP 5T Customer Input 5 Signal OSP 5R Customer Input 5 Ground OSP 6T Customer Input 6 Signal OSP 6R Customer Input 6 Ground OSP 7T Customer Input 7 Signal OSP 7R Customer Input 7 Ground OSP 8T Customer Input 8 Signal OSP 8R Customer Input 8 Ground OSP 9T Data to Tail OSP 9R Da...

Страница 177: ...OSP 17T 1 PPS to Head Sync Forward OSP 17R 1 PPS to Head OSP 18T RGPS 28V OSP 18R RGPS Ground OSP 18T RGPS 28V OSP 18R RGPS Ground OSP 19T RGPS 28V OSP 19R RGPS Ground Unused OSP20T Unused Unused OSP20R Unused OSP 21T RX TIP Primary Network OSP 21R RX RING Primary Network OSP 22T TX TIP Primary Network Span Network OSP 22R TX RING Primary Network Span Network OSP 23T RX TIP Secondary Network OSP 2...

Страница 178: ...ry Surge Suppressor punchdown block Sync Forward of the BTS Table 5 15 provides the punchdown block to RGPS connections Table 5 15 Connecting the RGPS to the Site I O Cable Punchdown Block RGPS Cable M Sync Forward Descriptions Punchdown Block Location RGPS Description RGPS Color Code wire stripe Data from Head OSP14T Transmit Port Green Black Data from Head OSP14R Transmit Port Green Data to Head...

Страница 179: ...1 interfaces for backhaul support Each interface is made up of Transmit Tip Ring and Receive Tip Ring connections The Transmit and Receive data flow is given from the perspective of the unit Only a single span line Primary is required for BTS operation Connecting a Phone Line to the Primary Surge Suppressor ModemSupport The unit provides a two wire analog phone line interface for modem support The...

Страница 180: ...equiredEquipment Cables The RGPS Synchronization Cable is contained in the Motorola kits listed in Table 5 16 Table 5 16 Cable Descriptions and Part Numbers Cable Qty Part Number Description X 1 11 3086039H18 RGPS Synchronization cable part of kit SGKN4351A 3086039H19 RGPS Synchronization cable part of kit SGKN4352A Motorola kits Table 5 17 and Table 5 18 show the contents of Motorola kits SGKN435...

Страница 181: ...ation ATP and FRU Procedures PRELIMINARY Cable Diagram Figure 5 25 and Figure 5 26 both show the cabling for multi unit configurations for both RGPS sychronous and HSO non synchronous Procedure Connect the cables Cable X between the Primary Surge Suppressors of each BTS Refer to the cable run list in Table 5 19 Figure 5 25 and Figure 5 26 5 ...

Страница 182: ...PS DAISY CHAIN CABLE RGPS DAISY CHAIN CABLE NOTE 1 EACH BTS MAY CONTAIN UP TO FOUR SC340 UNITS NOTE 2 A MAXIMUM OF 12 BTS MAY BE INTERCONNECTED WITH A MAXIMUM DASIY CHAIN CABLE LENGTH OF 600M BETWEEN EACH BTS A MAXIMUM OF SEVEN BTS MAY BE INTERCONNECTED WITH A MAXIMUM DAISY CHAIN CABLE LENGTH OF 1KM BETWEEN EACH BTS MAXIMUM DISTANCE IS 1 KM SEE NOTE 2 BTS 1 SEE NOTE 1 BTS 3 SEE NOTE 1 BTS 4 SEE NO...

Страница 183: ...DAISY CHAIN CABLE MAXIMUM DISTANCE IS 600M SEE NOTE 2 BTS 1 SEE NOTE 1 BTS 2 SEE NOTE 1 BTS 3 SEE NOTE 1 BTS 4 SEE NOTE 1 UNIT 4 UNIT 3 UNIT 2 UNIT 1 UNIT 3 UNIT 2 UNIT 1 UNIT 2 UNIT 1 UNIT 1 X X X MAXIMUM DISTANCE IS 600M SEE NOTE 2 MAXIMUM DISTANCE IS 600M SEE NOTE 2 DOWNSTREAM DOWNSTREAM DOWNSTREAM UPSTREAM UPSTREAM UPSTREAM NOTE 1 EACH BTS MAY CONTAIN UP TO FOUR SC340 UNITS NOTE 2 A MAXIMUM OF...

Страница 184: ...Cable X Sync Forward To BTS N 1 Punchblock Location Signal RGPS Cable Color Punchblock Location Signal OSP 9T Data to Tail Green Black OSP 14T Data from Head OSP 9R Data to Tail Green OSP 14R Data from Head OSP 10T Data from Tail White Black OSP 15T Data to Head OSP 10R Data from Tail White OSP 15R Data to Head OSP 11T 1 PPS to Tail Brown Black OSP 16T 1 PPS from Head OSP 11R 1 PPS to Tail Brown O...

Страница 185: ...n an open daisy chain loop using a single T1 JT1 E1 span This will reduce the number of spans necessary to support a JCDMA system and minimize unused channels Each BTS may contain up to four units A maximum of 12 BTSs may be combined in a single daisy chain Cable Description The following cables are necessary to do this procedure Table 5 20 Cable Descriptions and Part Numbers Cable Qty Part Number...

Страница 186: ...UPPRESSOR SITE I O CABLE CUSTOMER INPUTS SPAN PHONE MODEM SITE I O CABLE CUSTOMER INPUTS SPAN PHONE MODEM SITE I O CABLE CUSTOMER INPUTS SPAN PHONE MODEM SITE I O CABLE BTS 1 SEE NOTE 1 SPAN LINE DAISY CHAIN CABLE SPAN LINE DAISY CHAIN CABLE SPAN LINE DAISY CHAIN CABLE NOTE 1 EACH BTS SITE MAY CONTAIN UP TO FOUR SC340 UNITS THERE MAY BE A TOTAL OF 12 BTSs IN A DAISY CHAIN W W W BTS 2 SEE NOTE 1 BT...

Страница 187: ...ble refer to Table 5 14 in the Site I O Span Line RGPS and Modem Cabling for Sites Equipped with Optional Primary Surge Suppressor procedure The pin number and wire color are based on the Site I O cable The pin number corresponds to pins on the Site I O junction box connectors NOTE Table 5 21 Cable Run List for Span Line Daisy Chain Cabling BTS 1 Secondary Backhaul BTS 2 Primary Backhaul Punchdown...

Страница 188: ...Span Line Daisy Chain Cabling for Sites Equipped with Optional Primary Surge Suppressor continued PRELIMINARY SCt300 BTS Hardware Installation ATP and FRU Procedures DEC 2000 5 40 Notes 5 ...

Отзывы: