Attaching Surge Suppressor to Mounting Bracket
PRELIMINARY
SC
t
300 BTS Hardware Installation, ATP and FRU Procedures
DEC 2000
5-10
Objective
The objective of this procedure is to attach the optional Primary Surge
Suppressor to the mounting bracket. This procedure applies to mounting
brackets that are attached to a rack, wall or pole.
You must attach the Primary Surge Suppressor to the
mounting bracket before you install the unit cabling.
IMPORTANT
*
Background
The following procedures should be followed in order to mount the
surge suppressor to the mounting bracket. The unit attaches to the
mounting bracket with three (3) M6 screws.
Tools
The following tools and materials are required to attach the unit to the
mounting bracket.
S
Torque driver wrench, 1/4–in. hex female drive, 0–10 N–M
S
T30 Torx tamper bit
S
Three M6X19 screws (Motorola Part Number 0387541C03)
Procedure to Attach the Surge
Suppressor to the Mounting
Bracket
Use the procedure in Table 5-1 to attach the surge suppressor to the
mounting bracket. Refer to Figure 5-9.
Table 5-1: Procedure to Attach the Surge Suppressor to the Mounting
Bracket
Step
Action
1
Lift the unit and place it on the mounting bracket by aligning
the bracket’s upper arms into the rectangular cutouts in the
mounting tabs. The unit may need to be raised up slightly so
that the lower bracket flange does not contact the unit’s lower
surface.
2
Use a T30 Torx tamper bit to start, but not tighten, all three
screws in the location shown in Figure 5-9.
3
Use a T30 Torx tamper bit to torque the three mounting
screws to 5.0 N–M.