PMP 320 Hardware Installation
Installing the 600SSD Surge Suppressor
Installing the 600SSD Surge Suppressor
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
Use the following procedure to install the 600SSD Surge suppressor.
CAUTION
Observe caution when drilling through the wall of the building. Ensure that there are
no power lines, gas lines, water lines, or data lines in the wall at the desired location
where the drilling takes place.
Procedure 5-9 Installing the 600SSD Surge Suppressor
1
With the cable openings facing downward, install the 600SSD surge
suppressor above the site where the hole in the residence has been drilled.
Use two screws to attach the unit following regulatory building guidelines.
2
Connect the surge suppressor to Earth Ground. Refer to
Connecting the
CSM to the Ethernet cable, Earth Ground, the Surge Suppressor on page
6-13
. Refer to
Figure 6-7
.
3
Pack both of the 600SSD surge suppressor Ethernet jacks with dielectric
grease.
4
Include a splicing loop in the Ethernet cable from the CSM (extra cable to
allow future repositioning or reconnectorization) and position and secure the
Ethernet cable with UV-resistant wire ties or other locally-approved fasteners
so it forms a drip loop (so water drips off the cable instead of following the
cable into the 600SSD surge suppressor).
5
Connect the Ethernet connection from the CSM to the surge suppressor.
6
Build another Ethernet cable to span from the surge suppressor through
the residence wall to the area where the power injector will be placed in
the subscriber’s residence.
7
Guide the Ethernet cable through the grommet where the drilled hole was
made into the residence.
8
Seal the cable entry point into the building using accepted industry or local
practices.
9
Connect the Ethernet cable to the Data In port of the CSM power injector.
Refer to
Figure 6-8
.
Содержание PMP 320
Страница 1: ...PMP 320 Hardware Installation PMP320HDW2v1 JUL 2010 Preliminary 2010 Motorola Inc All Rights Reserved ...
Страница 8: ...Preliminary JUL 2010 iv PMP320HDW2v1 ...
Страница 31: ......
Страница 51: ...JUL 2010 Preliminary AP Hardware Installation complete Chapter 2 AP Hardware Installation 2 20 PMP320HDW2v1 ...
Страница 78: ...Preliminary JUL 2010 Chapter 4 Cables ...
Страница 85: ......
Страница 123: ...JUL 2010 Preliminary Chapter 7 Connectorized CSM Antenna Installation Instructions PMP320HDW2v1 7 1 ...
Страница 133: ...PMP320HDW2v1 7 31 JUL 2010 Preliminary Chapter 8 Regulatory Legal and Safety Notices ...
Страница 141: ...PMP320HDW2v1 8 39 Preliminary JUL 2010 inches PMP 320 AP At least 50 cm approximately 20 inches ...