4 FUNCTIONS
4.13 Logging Function
69
4
■
Setting the monitoring condition
• Set a condition to generate a hold trigger in 'CH1 Level trigger condition setting' (Un\G540).
• Set a value where a hold trigger is generated to 'CH1 Trigger setting value' (Un\G542).
The following figure shows the relation between setting items to be configured for the initial setting of a level
trigger.
For example if trying to generate a hold trigger when a value in 'CH1 Digital output value' (Un\G400) is greater
than 1000, set as follows.
• 'CH1 Level trigger condition setting' (Un\G540): Rise (1)
• 'CH1 Trigger data' (Un\G541): 400
• 'CH1 Trigger setting value' (Un\G542): 1000
Setting value
Description
1: Level trigger (Condition:
Rise)
(a) A hold trigger is generated when the relation between the values changes
from "Stored value of a buffer memory area to be monitored
≤
Trigger setting
value" to "Stored value of a buffer memory area to be monitored > Trigger
setting value".
(b) A hold trigger is generated when the relation between the values changes
from "Stored value of a buffer memory area to be monitored
≥
Trigger setting
value" to "Stored value of a buffer memory area to be monitored < Trigger
setting value".
A hold trigger is generated under the
condition (a).
2: Level trigger (Condition:
Fall)
A hold trigger is generated under the
condition (b).
3: Level trigger (Condition:
Rise and fall)
A hold trigger is generated under the
condition (a) or (b).
Item
Setting range
'CH1 Trigger setting value' (Un\G542)
-32768 to +32767
(a)
(b)
Stored value of a buffer memory area to be monitored
Time
Trigger setting
value
Set the address of a buffer memory area to be monitored.
Set a reference value to generate a trigger.
<
(Fall (2))
>
(Rise (1))
Set the condition.
The condition is
established.
CH
Level trigger condition
setting
> or <
(Rise and fall (3))
CH
Trigger setting value
-32768 to +32767
CH
Trigger data
CH
Digital operation value
CH
Digital output value
Level data
A trigger is
generated.