APPX
Appendix 4 Buffer Memory Areas
111
A
471
(1D7H)
671
(29FH)
871
(367H)
1071
(42FH)
1271
(4F7H)
1471
(5BFH)
1671
(687H)
1871
(74FH)
CH
Logging hold request
0
Control
472
(1D8H)
672
(2A0H)
872
(368H)
1072
(430H)
1272
(4F8H)
1472
(5C0H)
1672
(688H)
1872
(750H)
CH
Conversion value shift
amount
0
Control
473
(1D9H)
673
(2A1H)
873
(369H)
1073
(431H)
1273
(4F9H)
1473
(5C1H)
1673
(689H)
1873
(751H)
CH
Maximum value reset
request
0
Control
474
(1DAH)
674
(2A2H)
874
(36AH)
1074
(432H)
1274
(4FAH)
1474
(5C2H)
1674
(68AH)
1874
(752H)
CH
Minimum value reset
request
0
Control
475 to
500
(1DBH
to 1F4H)
675 to
700
(2A3H to
2BCH)
875 to
900
(36BH to
384H)
1075 to
1100
(433H to
44CH)
1275 to
1300
(4FBH
to 514H)
1475 to
1500
(5C3H
to
5DCH)
1675 to
1700
(68BH to
6A4H)
1875 to
1900
(753H to
76CH)
System area
501
(1F5H)
701
(2BDH)
901
(385H)
1101
(44DH)
1301
(515H)
1501
(5DDH)
1701
(6A5H)
1901
(76DH)
CH
Averaging process
specification
0
Setting
502
(1F6H)
702
(2BEH)
902
(386H)
1102
(44EH)
1302
(516H)
1502
(5DEH)
1702
(6A6H)
1902
(76EH)
CH
Time Average/Count
Average/Moving Average
setting
0
Setting
503
(1F7H)
703
(2BFH)
903
(387H)
1103
(44FH)
1303
(517H)
1503
(5DFH)
1703
(6A7H)
1903
(76FH)
System area
504
(1F8H)
704
(2C0H)
904
(388H)
1104
(450H)
1304
(518H)
1504
(5E0H)
1704
(6A8H)
1904
(770H)
CH
Scaling enable/disable
setting
1
Setting
505
(1F9H)
705
(2C1H)
905
(389H)
1105
(451H)
1305
(519H)
1505
(5E1H)
1705
(6A9H)
1905
(771H)
System area
506
(1FAH)
706
(2C2H)
906
(38AH)
1106
(452H)
1306
(51AH)
1506
(5E2H)
1706
(6AAH)
1906
(772H)
CH
Scaling upper limit
value
0
Setting
507
(1FBH)
707
(2C3H)
907
(38BH)
1107
(453H)
1307
(51BH)
1507
(5E3H)
1707
(6ABH)
1907
(773H)
System area
508
(1FCH)
708
(2C4H)
908
(38CH)
1108
(454H)
1308
(51CH)
1508
(5E4H)
1708
(6ACH)
1908
(774H)
CH
Scaling lower limit
value
0
Setting
509
(1FDH)
709
(2C5H)
909
(38DH)
1109
(455H)
1309
(51DH)
1509
(5E5H)
1709
(6ADH)
1909
(775H)
System area
510
(1FEH)
710
(2C6H)
910
(38EH)
1110
(456H)
1310
(51EH)
1510
(5E6H)
1710
(6AEH)
1910
(776H)
CH
Digital clipping enable/
disable setting
1
Setting
511
(1FFH)
711
(2C7H)
911
(38FH)
1111
(457H)
1311
(51FH)
1511
(5E7H)
1711
(6AFH)
1911
(777H)
System area
512
(200H)
712
(2C8H)
912
(390H)
1112
(458H)
1312
(520H)
1512
(5E8H)
1712
(6B0H)
1912
(778H)
CH
Alert output setting
(Process alarm)
1
Setting
513
(201H)
713
(2C9H)
913
(391H)
1113
(459H)
1313
(521H)
1513
(5E9H)
1713
(6B1H)
1913
(779H)
CH
Alert output setting
(Rate alarm)
1
Setting
514
(202H)
714
(2CAH)
914
(392H)
1114
(45AH)
1314
(522H)
1514
(5EAH)
1714
(6B2H)
1914
(77AH)
CH
Process alarm upper
upper limit value
0
Setting
515
(203H)
715
(2CBH)
915
(393H)
1115
(45BH)
1315
(523H)
1515
(5EBH)
1715
(6B3H)
1915
(77BH)
System area
516
(204H)
716
(2CCH)
916
(394H)
1116
(45CH)
1316
(524H)
1516
(5ECH)
1716
(6B4H)
1916
(77CH)
CH
Process alarm upper
lower limit value
0
Setting
517
(205H)
717
(2CDH)
917
(395H)
1117
(45DH)
1317
(525H)
1517
(5EDH)
1717
(6B5H)
1917
(77DH)
System area
518
(206H)
718
(2CEH)
918
(396H)
1118
(45EH)
1318
(526H)
1518
(5EEH)
1718
(6B6H)
1918
(77EH)
CH
Process alarm lower
upper limit value
0
Setting
519
(207H)
719
(2CFH)
919
(397H)
1119
(45FH)
1319
(527H)
1519
(5EFH)
1719
(6B7H)
1919
(77FH)
System area
520
(208H)
720
(2D0H)
920
(398H)
1120
(460H)
1320
(528H)
1520
(5F0H)
1720
(6B8H)
1920
(780H)
CH
Process alarm lower
lower limit value
0
Setting
521
(209H)
721
(2D1H)
921
(399H)
1121
(461H)
1321
(529H)
1521
(5F1H)
1721
(6B9H)
1921
(781H)
System area
522
(20AH)
722
(2D2H)
922
(39AH)
1122
(462H)
1322
(52AH)
1522
(5F2H)
1722
(6BAH)
1922
(782H)
CH
Rate alarm alert
detection cycle setting
0
Setting
Address
Decimal (hexadecimal)
Name
Default
value
Data
type
Auto
refresh
CH1
CH2
CH3
CH4
CH5
CH6
CH7
CH8