1 Outline
1.10 Restriction in number of units in each group
1
O
utline
2
Exter
nal
D
im
en
sions
3
Ge
ne
ric
Speci
ficat
ions
4
Pow
er Suppl
y
Specif
icati
ons
5
Input
Spec
ific
ations
6
O
utput
Specif
icat
ions
7
Exam
pl
es
of
W
iri
ng
fo
r
Va
rious U
ses
8
Te
rm
inal B
lock
9
CC
-L
in
k/L
T
Ma
ste
r F
X
3UC
(LT
only)
10
D
ispl
ay m
odule
FX
3UC
(L
T only)
I/O extension devices
Special function devices
- Special function units
- Special function blocks
In addition to the restrictions shown on the previous page, the number of units
connectable to the main unit or extension power supply unit is restricted in the
following models.
*1. When the FX
0N
-3A, FX
2N
-2AD or FX
2N
-2DA is used, up to 4 units in total can
be connected. When the FX
0N
-3A, FX
2N
-2AD or FX
2N
-2DA is not used, up to
5 units in total can be connected.
*2. Consider the restriction for the number of special function equipment.
Note that the number of connectable units is restricted for the following special
function units/blocks.
Division
Contents of restrictions
C
D
Model name
Connection target and number of connectable units
FX
3UC
-
MT/D
FX
3UC
-1PS-5V
FX
2NC
-16EYR-T
When the FX
2NC
-16EYR-T is
not used, up to 4 units in total
can be connected.
When the FX
2NC
-16EYR-T is
used, refer to the note
*1
below.
Up to 5 units in total can
be connected.
FX
2N
-8ER
FX
2N
-8EYR
FX
2N
-8EYT
FX
2N
-8EYT-H
FX
2N
-16EYR
FX
0N
-3A
*2
FX
2N
-2AD
*2
FX
2N
-2DA
*2
A
A
E
Model name
Connection target and number of connectable units
FX
3UC
-
MT/DSS
FX
3UC
-1PS-5V
FX
2NC
-16EYR-T-DS
When the FX
2NC
-16EYR-T-
DS is not used, up to 4 units
in total can be connected.
When the FX
2NC
-16EYR-T-
DS is used, refer to the note
*1
below.
Up to 5 units in total can
be connected.
FX
2N
-8ER-ES/UL
FX
2N
-8EYR-ES/UL
FX
2N
-8EYT-ESS/UL
FX
2N
-16EYR-ES/UL
FX
0N
-3A
*2
FX
2N
-2AD
*2
FX
2N
-2DA
*2
A
A
E
Model name
Restrictions
FX
2N
-16CCL-M
• It cannot be used together with the FX
2N
-32ASI-M.
- When some units are used, a remote I/O station
cannot be connected to the second or following
master stations.
FX
2N
-32ASI-M
• It cannot be used together with the FX
2N
-16CCL-M.
- Only one unit can be used for the whole system.
FX
2N
-1RM-SET
FX
2N
-1RM-E-
SET
Up to 3 units can be sequentially connected to the end of a
system. However, when three units are connected, they are
counted as one unit, and the number of input/output
occupied points is 8.