10 Display Module (Only FX3UC-32MT-LT)
10.6 Monitor/Test Mode [User-Registered Devices]
10.6
Monitor/Test Mode [User-Registered Devices]
Regarding user-registered devices at "Monitor/Test" menu, monitor and test operations can be performed for
a maximum of 4 data registers (16-bit/32-bit) specified by the system information.
→
Refer to Section 10.20 for the user-registered device setting procedure.
10.6.1 Monitor mode operation
1) At the menu screen, use the [+] and [-] buttons to move the cursor
to the "Monitor/Test" item, then press [OK] to display the "Main unit
I/O operation display" shown to the right.
To cancel the operation and return to the "main unit I/O operation
display", press [ESC] at the menu screen
2) "Use the [+] and [-] buttons to move the cursor to the "User" item.
To cancel the operation and return to the "device selection screen",
press [ESC].
3) Press [OK] to display the data registers specified by the system
information.
The first time the power is turned on, the display begins with device
No.1 of the "user-registered devices". At subsequent power ONs,
the device which was being monitored at the previous operation is
displayed.
If a specified user-registered device has been changed, the newly
specified device is displayed.
To cancel the operation and return to the "device selection screen", press [ESC].
4) Use the [+] and [-] buttons to scroll the user-registered devices
screen.
To cancel the operation and return to the "device selection screen",
press [ESC].
Display Content
[1]
Device comments (registered at the PLC) are displayed together with the devices.
If no device comment has been registered, the device comment area is left blank.
[2]
Device included in the user-registered devices
[3]
Current value
Button
Operation Description
ESC
Returns to the "device selection screen".
-
Scrolls the user-registered devices.
(User-specified device 1
→
user-specified device 4
→
user-specified device 3
→
user-specified
device 2
→
user-specified device 1)
+
Scrolls the user-registered devices.
(User-specified device 1
→
user-specified device 2
→
user-specified device 3
→
user-specified
device 4
→
user-specified device 1)
OK
Switches to the test mode when hold for 1 second or longer.
D ( 1 6 b i
DD ( 3 2
T
C
t )
b i t )
R ( 1 6 b i
DR ( 3 2
t )
b i t )
E R ( 1 6 b i t )
E R ( 3 2 b i t )
D
X
Y
M
S
U s e r
D 1 0 0
1 0
[1]
[2]
[3]
H a l f
t i m e r
D 1 0 3
0
D 1 0 4
Содержание FX3UC Series