1 Outline
1.6 System overall configuration
1.6
System overall configuration
Products connectable to the FX
3UC
PLC are classified into the groups
to
as shown below.
For model names of products classified into the
and
groups, refer to "1.11 Number of input/output
occupied points and 5V DC current consumption of each model".
A
G
C
D
Group
Group
Group
Special
adapter
Expansion
board
extension
I/O
Special
extension
I/O
FX
2NC
FX
2NC
-CNV-IF
FX
3UC
-1PS-5V
FX
3UC
-1PS-5V
FX
3UC
-1PS-5V
FX
3UC
-1PS-5V
(FX
3UC
/FX
2NC
Series)
Either
(FX
3U
/FX
2N
/FX
0N
Series)
Range to be covered by main unit
I/O
FX
2N
I/O
FX
0N
Special
FX
3UC
function
Special
FX
2N
FX
3U,
function
Special
FX
2NC
function
Special
FX
0N
function
I/O
FX
2NC
I/O
FX
2N
I/O
FX
0N
Special
FX
3UC
function
Special
FX
2N
FX
3U,
function
Special
FX
2NC
function
I/O
FX
2NC
I/O
FX
2NC
Special
FX
3UC
function
Special
FX
3UC
function
Special
FX
2NC
function
Special
FX
2NC
function
I/O
FX
2NC
Special
FX
3UC
function
Special
FX
2NC
function
Special
FX
0N
function
I/O
FX
2N
I/O
FX
0N
Special
FX
2N
FX
3U
function
Special
FX
0N
function
Special adapter
(Analog)
Special adapter
(communication)
Expansion board
(Only FX
3UC
-32MT-LT)
FX
3UC
Main unit
Group
Remote
I/O
Remote
I/O
Remote
I/O
Remote
I/O
(Only FX
3UC
-32MT-LT)
GOT
Programming tool
FX
3U
/FX
3UC
Option
FX
3UC
/FX
2NC
/FX
3U
/FX
2N
/FX
0N
Series extension devices (example)
Range to be covered by
main unit
Range to be covered by
main unit
Range to be covered by
FX
3UC
-1PS-5V
The power supply for the built-in CC-Link/LT
module in the FX
3UC
-32MT-LT can connect
remote I/O stations whose total current
consumption is 350 mA or less.
A power supply adapter for CC-Link/LT, etc.
is required when the power supply is
insufficient.
For details, refer to the Manual (CC-Link/LT).
FX
2NC
-CNV-IF
FX
3UC
-1PS-5V
:
FX
3U
/FX
2N
/FX
0N
Series extension equipment can be
connected.
:
FX
3UC
/FX
2NC
Series extension equipment or
FX
3U
/FX
2N
/FX
0N
Series extension equipment can be
connected.
Connection constructed using only the built-in power supply
(FX
3U
/FX
2N
/FX
0N
Series extension)
Connection when the built-in power supply is insufficient
(FX
3UC
/FX
2NC
Series extension)
Connection when the built-in power supply is insufficient
Range to be covered by
FX
3UC
-1PS-5V (1st unit)
Range to be covered by
FX
3UC
-1PS-5V (2nd unit)
To FX
3UC
-1PS-5V (2nd unit)
FX
3U
-4AD-ADP
FX
3U
-4DA-ADP
FX
3U
-4AD-PT-ADP
FX
3U
-4AD-TC-ADP
FX
3U
-232ADP(-MB)
FX
3U
-485ADP(-MB)
FX
3U
-232-BD
FX
3U
-422-BD
FX
3U
-485-BD
FX
3U
-USB-BD
FX
3U
-CNV-BD
Содержание FX3UC Series
Страница 1: ...USER S MANUAL Hardware Edition FX3UC SERIES PROGRAMMABLE CONTROLLERS ...
Страница 2: ......
Страница 454: ...448 FX3UC Series Programmable Controllers User s Manual Hardware Edition F Discontinued models MEMO ...
Страница 457: ......