435
FX
3UC
Series Programmable Controllers
User’s Manual - Hardware Edition
C Operation of Special Devices (M8000 -, D8000 -)
C-2 Special Data Register (D8000 to D8511)
11
Mem
ory
Cass
ette/B
attery
12
Te
st
R
un,
M
aint
enanc
e,
Troubleshoot
ing
A
Ve
rs
ion
In
fo
rm
atio
n
B
Per
for
m
ance
Specif
icati
ons
C
S
pec
ia
l D
evices
(M80
00 -,
D
800
0 -)
D
In
str
uct
ion List
E
C
har
ac
te
r-code
F
D
isconti
nued
m
odels
High Speed Counter Comparison, High Speed Table, and Positioning
[D]8130
HSZ (FNC 55) instruction:
High speed comparison table
counter
M8130
[D]8131
HSZ (FNC 55) and PLSY (FNC 57)
instructions:
Speed pattern table counter
M8132
[D]8132
Lower HSZ (FNC 55) and PLSY
(FNC 57) instructions:
Speed pattern frequency
M8132
[D]8133
Upper
[D]8134
Lower HSZ (FNC 55) and PLSY
(FNC 57) instructions:
Number of target pulses for
speed pattern
M8132
[D]8135
Upper
D
8136
Lower PLSY (FNC 57), PLSR
(FNC 59) instructions:
Accumulated total number
of pulses output to Y000
and Y001
–
D 8137
Upper
[D]8138
HSCT (FNC280) instruction:
Table count
D8138
[D]8139
HSCS (FNC 53), HSCR (FNC 54),
HSZ (FNC 55), and HSCT
(FNC280) instructions:
Number of instructions being
executed
D8139
D 8140
Lower Accumulated number of
pulses output to Y000 for
PLSY (FNC 57) and PLSR
(FNC 59) instructions, or
current address of Y000 for
positioning instruction
–
D 8141
Upper
D 8142
Lower Accumulated number of
pulses output to Y001 for
PLSY (FNC 57) and PLSR
(FNC 59) instructions, or
current address of Y001 for
positioning instruction
–
D 8143
Upper
[D]8144 to [D]8149 Not used
–
Inverter Communication Function
D 8150
Response wait time of inverter
communication [ch1]
–
[D]8151
Step number of instruction during
inverter communication [ch1]
Default: -1
M8151
[D]8152
*1
Error code for inverter
communication [ch1]
M8152
[D]8153
Inverter communication error step
number latched [ch1]
Default: -1
M8153
[D]8154
Parameter number when error
occurs during IVBWR (FNC274)
instruction [ch1]
Default: -1
M8154
D 8155
Response wait time of inverter
communication [ch2]
–
[D]8156
Step number of instruction during
inverter communication [ch2]
Default: -1
M8156
Number and
name
Content of register
Correspond-
ing special
device
[D]8157
*1
Error code for inverter
communication [ch2]
M8157
[D]8158
Inverter communication error step
number latched [ch2]
Default: -1
M8158
[D]8159
Parameter number when error
occurs during IVBWR (FNC274)
instruction [ch2]
Default: -1
M8159
*1. Cleared when PLC switches from STOP to RUN.
Advanced Function
[D]8160
Not used
–
[D]8161
–
[D]8162
–
[D]8163
–
D 8164
–
[D]8165
–
[D]8166
–
[D]8167
–
[D]8168
–
[D]8169
*2
Access restriction status by 2nd
keyword
*3
–
*2.
Supported in Ver. 2.20 or later
*3. Access restriction status by 2nd keyword
*4. The accessibility is restricted depending on the keyword
setting status.
Number and
name
Content of register
Correspond-
ing special
device
Present
value
Access restriction
status
Program
Monitor-
ing
Present
value
change
Read Write
H0000 2nd keyword is not set.
*4
*4
*4
*4
H0010 Write protection
–
H0011 Read / write protection
–
–
H0012
All online operation
protection
–
–
–
–
H0020 Keyword cancel
Содержание FX3UC Series
Страница 1: ...USER S MANUAL Hardware Edition FX3UC SERIES PROGRAMMABLE CONTROLLERS ...
Страница 2: ......
Страница 454: ...448 FX3UC Series Programmable Controllers User s Manual Hardware Edition F Discontinued models MEMO ...
Страница 457: ......