FX2N-16CCL-M CC-Link System Master Block
Functions 5
5-3
[Remote input]
3) The input status of the remote I/O stations is automatically (for each link scan) stored in the
buffer memory "remote input (RX)" in the master station.
4) The PLC receives the input status stored in the buffer memory "remote input (RX)" using
the FROM instruction.
[Remote output]
5) The PLC writes the ON/OFF information output from the remote I/O station to the buffer
memory "remote output (RY)" using the TO instruction.
6) The output status stored in the buffer memory "remote output (RY)" is automatically (for
each link scan) output from the remote I/O stations.
Master station
RX0F ~ RX00
RX1F ~ RX10
RX2F ~ RX20
RX3F ~ RX30
RX4F ~ RX40
~
RX1DF ~ RX1D0
PLC
FROM
X0F ~ X00
X0F ~ X00
Remote I/O station
(Station No. 1: Occupies 1 station)
Remote I/O station
(Station No. 2: Occupies 1 station)
32-point module
16-point module
Remote input (RX)
X1F ~ X10
Y0F ~ Y00
Y1F ~ Y10
Master station
RY0F ~ RY00
RY1F ~ RY10
RY2F ~ RY20
RY3F ~ RY30
RY4F ~ RY40
~
RY1DF ~ RY1D0
PLC
TO
Remote I/O station
(Station No. 3: Occupies 1 station)
Remote I/O station
(Station No. 4: Occupies 1 station)
32-point module
16-point module
RY5F ~ RY50
RY6F ~ RY60
RY7F ~ RY70
RY8F ~ RY80
Remote output (RY)
Y0F ~ Y00
Содержание FX2N-16CCL-M
Страница 4: ...FX2N 16CCL M CC Link System Master Block ii ...
Страница 6: ...FX2N 16CCL M CC Link System Master Block iv ...
Страница 34: ...FX2N 16CCL M CC Link System Master Block System Configuration 3 3 14 MEMO ...
Страница 66: ...FX2N 16CCL M CC Link System Master Block Specification 4 4 32 MEMO ...
Страница 144: ...FX2N 16CCL M CC Link System Master Block Programming 9 9 16 MEMO ...
Страница 172: ...FX2N 16CCL M CC Link System Master Block Communication in Compound System 12 12 10 MEMO ...
Страница 192: ...FX2N 16CCL M CC Link System Master Block Appendix 14 14 4 MEMO ...
Страница 193: ......