FX2N-16CCL-M CC-Link System Master Block
Programming 9
9-9
Number
Buffer memory
Name
Description
Number
Bit
SB0075
5E7
H
5
Error invalid station
specification status
Indicates the error invalid station specification status
by parameter (SW0078).
OFF : Not specified
ON : Specified
SB0076
5E7
H
6
Temporary error
invalid station
specification status
Indicates the temporary error invalid station
specification status (SW007C).
OFF : Not specified
ON : Specified
SB0078
5E7
H
8
Switch change
status in host
station
Detects change in the setting switches in the host
station during data link.
OFF : No change
ON : Change
SB0080
5E8
H
0
Data link status in
other stations
Indicates the data link status with remote stations
(SW0080).
OFF : All stations are normal.
ON : Some stations are faulty.
SB0081
5E8
H
1
Watchdog timer
error status in
other stations
Indicates the watchdog timer error occurrence status
in other stations (SW0084).
OFF : No error
ON : Error
SB0082
5E8
H
2
Fuse blowout
status in other
stations
Indicates the fuse blowout occurrence status in other
stations (SW0088).
OFF : No error
ON : Error
SB0083
5E8
H
3
Switch change
status in other
stations
Detects change in the setting switches in other
stations during data link (SW008C).
OFF : No change
ON : Change
Содержание FX2N-16CCL-M
Страница 4: ...FX2N 16CCL M CC Link System Master Block ii ...
Страница 6: ...FX2N 16CCL M CC Link System Master Block iv ...
Страница 34: ...FX2N 16CCL M CC Link System Master Block System Configuration 3 3 14 MEMO ...
Страница 66: ...FX2N 16CCL M CC Link System Master Block Specification 4 4 32 MEMO ...
Страница 144: ...FX2N 16CCL M CC Link System Master Block Programming 9 9 16 MEMO ...
Страница 172: ...FX2N 16CCL M CC Link System Master Block Communication in Compound System 12 12 10 MEMO ...
Страница 192: ...FX2N 16CCL M CC Link System Master Block Appendix 14 14 4 MEMO ...
Страница 193: ......