84
3 SIGNALS AND WIRING
3.8 Grounding
3.8
Grounding
The servo amplifier supplies power to the servo motor by switching on and off a power transistor. Depending on the wiring and
ground wire routing, the servo amplifier may be affected by the switching noise (due to di/dt and dv/dt) of the transistor. To
prevent such a fault, refer to the following diagram and ground it.
To conform to the EMC Directive, refer to "EMC Installation Guidelines".
V
U
U
V
W
W
CN2
L11
L1
L2
L3
L21
MC
MCCB
M
Cabinet
Servo amplifier
Servo motor
Line filter
Encoder
Power supply
Connect the wire to the PE terminal of the servo
amplifier. Do not connect the wire directly to the
protective earth of the cabinet.
Outer box
Protective earth (PE)