3 SIGNALS AND WIRING
3.2 I/O signal connection example
33
3
Speed control mode
■
For sink I/O interface
*1 To prevent an electric shock, connect the protective earth (PE) terminal (the terminal marked with the
symbol) of the servo amplifier
to the protective earth (PE) of the cabinet.
*2 Connect the diode in the correct direction. If it is connected reversely, the servo amplifier may malfunction and not output signals,
disabling protective circuits such as EM2 (Forced stop 2).
*3 Install a forced stop switch (normally closed contact).
*4 Supply 24 V DC
10 % to interfaces from outside. The total current capacity of these power supplies is 500 mA maximum. The
amperage will not exceed 500 mA when all I/O signals are used. The current capacity can be decreased by reducing the number of I/O
points. For the amperage required for interfaces, refer to the following.
Page 76 Digital input interface DI-1
The illustration of the 24 V DC power supply is divided between input signal and output signal for convenience. However, they can be
configured by one.
*5 When starting operation, turn on EM2 (Forced stop 2), LSP (Forward rotation stroke end), and LSN (Reverse rotation stroke end)
(normally closed contact).
*6 If no alarm is occurring, ALM (Malfunction) is on (normally closed contact).
*7 The pins with the same signal name are connected in the servo amplifier.
*8 TLA will be available when TL (External torque limit selection) is enabled with servo parameters ([Pr. PD03] to [Pr. PD22]).
MR-J5 User's Manual (Function)
*9 Use SW1DNC-MRC2-_.
*10 If not using the STO function, attach the short-circuit connector that came with the servo amplifier.
*11 To prevent an unexpected restart of the servo amplifier, configure a circuit that turns off EM2 when the main circuit power supply is
turned off.
46
DOCOM
48
ALM
23
ZSP
25
TLC
24
SA
4
LA
5
LAR
6
LB
7
LBR
34
LG
33
OP
SD
CN3
*7
42
15
19
17
18
43
44
21
EM2
SON
RES
ST1
ST2
LSP
LSN
DICOM
CN3
*7
CN3
*7
1
2
SD
P15R
VC
LG
28
CN5
CN8
*1
MO1
MO2
3
LG
1
2
DC ± 10 V
DC ± 10 V
CN6
*2
RA2
RA3
RA4
RA1
47
DOCOM
49
RD
8
LZ
9
LZR
41
SP1
16
SP2
20
DICOM
*5
TLA
27
RA5
*4
*4
MR Configurator2
*9
+
Servo amplifier
10 m or less
10 m or less
Main circuit power supply
*11
24 V DC
Forced stop 2
*3*5
Servo-on
Reset
Speed selection 1
Malfunction
*6
Speed selection 2
Zero speed detection
Forward rotation start
Reverse rotation start
Limiting torque
Forward rotation stroke end
Speed reached
Reverse rotation stroke end
Ready
24 V DC
Upper limit setting
Encoder Z-phase pulse
(differential line driver)
Analog speed command
±10 V/rated speed
Encoder A-phase pulse
(differential line driver)
Upper limit setting
Analog torque limit
*8
+10 V/maximum torque
Encoder B-phase pulse
(differential line driver)
Plate
Control common
2 m or less
Encoder Z-phase pulse (open collector)
Plate
2 m or less
USB cable
(option)
Analog monitor 1
Analog monitor 2
2 m or less
Short-circuit connector
*10
(Packed with the servo amplifier)
Personal computer
Содержание MR-J5 Series
Страница 1: ...MR J5 User s Manual Hardware MR J5 _G_ MR J5W_ _G MR J5 _A_ Mitsubishi Electric AC Servo System ...
Страница 2: ......
Страница 315: ......